文献速递腹部CT

AI软件检出超过半数放射科医生在增强CT上漏诊的肝转移瘤

Artificial intelligence-powered software detected more than half of the liver metastases overlooked by radiologists on contrast-enhanced CT.
PubMed 文献 · Eur J Radiol · 2023-04-07

该研究回顾性分析了137例肝转移瘤患者的既往增强CT,其中68例为放射科医生漏诊病例。AI软件对全部肝病灶、肝转移瘤及漏诊肝转移瘤的病灶敏感度分别为70.1%、70.8%和55.0%,平均每例假阳性0.48个。结论认为AI软件能检出超过半数被放射科医生漏诊的肝转移瘤,且假阳性较低。

要点

  • AI软件对放射科医生漏诊的肝转移瘤病灶敏感度达55.0%,可辅助减少漏诊。
  • AI软件对全部肝病灶和肝转移瘤的病灶敏感度分别为70.1%和70.8%。
  • 平均每例假阳性0.48个,假阳性负担较低。

核心结论

  • AI软件能检出超过半数被放射科医生漏诊的肝转移瘤,且假阳性数量相对较低,提示其与放射科医生解读联合使用可减少漏诊。

研究设计与样本

  • 回顾性研究,纳入746例确诊肝转移瘤患者的记录,最终137例有可用的既往增强CT图像,其中68例为漏诊病例。
  • 由两名腹部放射科医生建立病灶ground truth,并与软件输出进行比对,主要终点为检出所有肝病灶类型、肝转移瘤及放射科医生漏诊的肝转移瘤的敏感度。

诊断标准与关键数值

  • AI软件对所有肝病灶类型的病灶敏感度为70.1%。
  • AI软件对肝转移瘤的病灶敏感度为70.8%。
  • AI软件对放射科医生漏诊的肝转移瘤的病灶敏感度为55.0%。
  • AI软件在检出病例和漏诊病例中的患者水平肝转移瘤检出率分别为92.7%和53.7%。
  • 平均每例假阳性数为0.48个。

临床应用与阅片要点

  • 在日常阅片增强CT时,可将AI软件作为第二读者辅助检出肝转移瘤,尤其关注易漏诊病灶。
  • 需注意AI软件存在一定假阳性(平均每例0.48个),应结合临床和影像特征综合判断。

局限性

  • 本研究为回顾性设计,样本来自单中心,可能存在选择偏倚。
  • 仅137例患者纳入最终分析,样本量有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the sensitivity of artificial intelligence (AI)-powered software in detecting liver metastases, especially those overlooked by radiologists.

METHODS: Records of 746 patients diagnosed with liver metastases (November 2010-September 2017) were reviewed. Images from when radiologists first diagnosed liver metastases were reviewed, and prior contrast-enhanced CT (CECT) images were checked for availability. Two abdominal radiologists classified the lesions into overlooked lesions (all metastases missed by radiologists on prior CECT) and detected lesions (all metastases if any of them were correctly identified and invisible on prior CECT or those with no prior CECT). Finally, images from 137 patients were identified, 68 of which were classified as "overlooked cases." The same radiologists created the ground truth for these lesions and compared them with the software's output at 2-month intervals. The primary endpoint was the sensitivity in detecting all liver lesion types, liver metastases, and liver metastases overlooked by radiologists.

RESULTS: The software successfully processed images from 135 patients. The per-lesion sensitivity for all liver lesion types, liver metastases, and liver metastases overlooked by radiologists was 70.1%, 70.8%, and 55.0%, respectively. The software detected liver metastases in 92.7% and 53.7% of patients in detected and overlooked cases, respectively. The average number of false positives was 0.48 per patient.

CONCLUSION: The AI-powered software detected more than half of liver metastases overlooked by radiologists while maintaining a relatively low number of false positives. Our results suggest the potential of AI-powered software in reducing the frequency of overlooked liver metastases when used in conjunction with the radiologists' clinical interpretation.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Nakai, Sakamoto, Kakigi, et al. Artificial intelligence-powered software detected more than half of the liver metastases overlooked by radiologists on contrast-enhanced CT. Eur J Radiol. 2023. PMID: 37059006. doi:10.1016/j.ejrad.2023.110823

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。