球囊扩张治疗肺移植后支气管狭窄:单中心10年经验
回顾性分析50例肺移植后支气管狭窄患者共65个支气管的277次球囊扩张治疗,技术成功率99.3%,无重大并发症。初次通畅率仅18.5%,重复扩张后二次通畅率76.9%,5年二次通畅率78.5%。有临床症状与初次通畅率降低相关,早期治疗(≤6个月)和延长球囊扩张(>5分钟)与更高二次通畅率相关。
要点
- 球囊扩张治疗肺移植后支气管狭窄技术成功率高、安全性好,无重大并发症。
- 初次通畅率低(18.5%),但重复球囊扩张可显著提高二次通畅率至76.9%。
- 早期治疗(≤6个月)和延长球囊扩张时间(>5分钟)与更好的长期通畅率相关。
局限性
- 单中心回顾性研究,样本量有限(50例患者、65个支气管)。
- 原文未报告对照组或与其他治疗方式的比较。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To assess the safety and efficacy of balloon dilatation under dual guidance using fluoroscopy and bronchoscopy for treating bronchial stenosis following lung transplantation (LT), and to elucidate the factors associated with patency after the procedure.
MATERIALS AND METHODS: From September, 2012, to April, 2021, 50 patients (mean age ± standard deviation, 54.4 ± 12.2 years) with bronchial stenosis among 361 recipients of LT were retrospectively analyzed. The safety of balloon dilatation was assessed by evaluating procedure-related complications. Efficacy was assessed by evaluating the technical success, primary patency, and secondary patency. Primary and secondary cumulative patency rates were calculated using the Kaplan-Meier method. The factors associated with patency after the procedure were evaluated using multivariable Cox hazard proportional regression analysis.
RESULTS: In total, 65 bronchi were treated with balloon dilatation in 50 patients. The total number of treatment sessions was 277 and the technical success rate was 99.3% (275/277 sessions). No major procedure-related complications were noted. During the mean follow-up period of 34.6 ± 30.8 months, primary patency was achieved in 12 of 65 bronchi (18.5%). However, the patency rate improved to 76.9% (50 of 65 bronchi) after repeated balloon dilatation (secondary patency). The 6-month, 1-year, 3-year, and 5-year secondary patency rates were 95.4%, 90.8%, 83.1%, and 78.5%, respectively. The presence of clinical symptoms was a significant prognostic factor associated with reduced primary patency (adjusted hazard ratio [HR], 0.465; 95% confidence interval [CI], 0.220-0.987). Early-stage treatment ≤ 6 months (adjusted HR, 3.588; 95% CI, 1.093-11.780) and prolonged balloon dilatation > 5 min (adjusted HR, 3.285; 95% CI, 1.018-10.598) were associated with significantly higher secondary patency.
CONCLUSION: Repeated balloon dilatation was determined to be safe and effective for treating bronchial stenosis following LT. Early-stage treatment and prolonged balloon dilatation could significantly promote long-term patency.