胎儿心血管结构的定量测量与形态学评估:胎儿心脏MRI研究

Quantitative measurements and morphological evaluation of fetal cardiovascular structures with fetal cardiac MRI.
PubMed 文献 · Eur J Radiol · 2023-04-08

前瞻性纳入120例孕19-37周孕妇,采用SSFP序列行胎儿心脏MRI,评估心血管形态并测量各结构尺寸。最终100例完成分析,所有直径测量与孕周高度相关;在超声图像质量不足时,FCMR可辅助诊断。

要点

  • FCMR可测量胎儿心腔、大血管及静脉直径,且与孕周高度相关。
  • SSFP序列扫描时间短,无需母胎镇静即可获得足够图像质量。
  • 肺静脉显示率有限:4支49%、3支33%、2支18%,阅片需注意。

核心结论

  • 在超声无法获得足够图像质量时,胎儿心脏MRI可辅助诊断。
  • SSFP序列采集时间短且采用并行成像技术,无需母胎镇静即可获得 adequate 图像质量。
  • 所有直径测量值均与孕周呈高相关性。

研究设计与样本

  • 前瞻性研究,纳入120例孕19-37周孕妇,最终100例完成分析。
  • 纳入标准为超声无法排除心脏异常或因疑似非心血管系统病变转诊行MRI。
  • 采用轴位、冠状位和矢状位多层稳态自由进动(SSFP)序列及实时非触发SSFP序列,根据胎心轴获取图像。
  • 评估心血管结构形态及其相互关系并测量尺寸。

关键影像表现/征象

  • 所有胎儿均测量了心腔直径、心脏直径、心脏长径、心脏面积、胸廓直径和胸廓面积。
  • 所有胎儿均测量了升主动脉、主动脉峡部、降主动脉、主肺动脉、动脉导管、上腔静脉和下腔静脉直径。
  • 左肺动脉显示率为89%(89例),右肺动脉显示率为99%(99例)。
  • 四支肺静脉显示率49%(49例),三支33%(33例),两支18%(18例)。

临床应用与阅片要点

  • 当超声因图像质量不足无法充分评估胎儿心血管结构时,可考虑FCMR作为补充检查。
  • 采用SSFP序列无需母胎镇静,扫描时间短,适合胎儿成像。
  • 肺静脉显示率有限(4支仅49%),报告时应注意肺静脉显示数目。

局限性

  • 7例(6.3%)因运动伪影无法评估和测量心血管形态而被排除。
  • 3例(2.9%)因图像分析发现心脏病变而被排除。
  • 肺静脉显示率有限,可能影响肺静脉异常的检出。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Fetal cardiac magnetic resonance imaging (FCMR) can be used as an imaging modality in fetal cardiovascular evaluation as studied in recent years. We aimed to evaluate cardiovascular morphology using FCMR and to observe the development of cardiovascular structures according to gestational age (GA) in pregnant women.

METHOD: In our prospective study, 120 pregnant women between 19 and 37 weeks of gestation in whom absence of cardiac anomaly could not be excluded by ultrasonography (US) or, who were referred to us for magnetic resonance imaging (MRI) for suspected non-cardiovascular system pathology, were included. According to the axis of the fetal heart, axial, coronal, and sagittal multiplanar steady-state free precession (SSFP) and 'real time' untriggered SSFP sequence, respectively, were obtained. The morphology of the cardiovascular structures and their relationships with each other were evaluated, and their sizes were measured.

RESULTS: Seven cases (6.3%) contained motion artefacts that did not allow the assessment and measurement of cardiovascular morphology, and three (2.9%) cases with cardiac pathology in the analysed images were excluded from the study. The study included a total of 100 cases. Cardiac chamber diameter, heart diameter, heart length, heart area, thoracic diameter, and thoracic area were measured in all fetuses. The diameters of the aorta ascendens (Aa), aortic isthmus (Ai), aorta descendens (Ad), main pulmonary artery (MPA), ductus arteriosus (DA, superior vena cava (SVC), and inferior vena cava (IVC) were measured in all fetuses. The left pulmonary artery (LPA) was visualised in 89 patients (89%). The right PA (RPA) was visualised in 99 (99%) cases. Four pulmonary veins (PVs) were seen in 49 (49%) cases, three in 33 (33%), and two in 18 (18%). High correlation values were found for all diameter measurements performed with GW.

CONCLUSION: In cases where US cannot achieve adequate image quality, FCMR can contribute to diagnosis. The very short acquisition time and parallel imaging technique with the SSFP sequence allow for adequate image quality without maternal or fetal sedation.

来源:Eur J Radiol,查看原文。版权归原作者所有。