冠状动脉造影衍生的FFR评估狭窄:PET与有创热稀释法验证
前瞻性观察性研究纳入250例疑似阻塞性冠心病患者,以82Rb-PET为参考标准,比较QFR与有创FFR对中间狭窄的诊断性能;结果显示两者在患者水平和血管水平的准确率相似,QFR无导丝方案可行。
要点
- QFR与有创FFR诊断准确率相似,患者水平73%对71%,血管水平70%对68%。
- FFR每增加0.10,PET应激心肌血流量增加0.14 mL/g/min;QFR每增加0.10,增加0.08 mL/g/min。
- QFR血管水平可行性84%,FFR为88%(意向诊断分析)。
核心结论
- 以82Rb-PET为参考,无导丝QFR与有创FFR在评估中间冠状动脉狭窄时诊断准确率相似。
研究设计与样本
- 前瞻性观察性研究,纳入250例患者320条血管,所有中间狭窄(直径狭窄30%-90%)均接受82Rb-PET和有创冠状动脉造影及FFR、QFR评估。
诊断标准与关键数值
- 参考标准为血管扩张时心肌血流量<2 mL/g/min和/或相对灌注异常( summed stress score ≥4 在≥2个相邻节段)。
- QFR患者水平准确率73%(95%CI 67%-79%),血管水平70%(95%CI 64%-75%)。
- FFR患者水平准确率71%(95%CI 64%-78%),血管水平68%(95%CI 62%-73%)。
- QFR血管水平可行性84%(95%CI 80%-88%),FFR为88%(95%CI 85%-92%)。
- FFR每增加0.10,PET应激心肌血流量增加0.14 mL/g/min(95%CI 0.07-0.21);QFR每增加0.10,增加0.08 mL/g/min(95%CI 0.02-0.14)。
临床应用与阅片要点
- QFR可作为无导丝功能学评估中间狭窄的替代工具,诊断性能与FFR相近。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Fractional flow reserve (FFR) derived from invasive coronary angiography (QFR) is promising for evaluation of intermediate coronary artery stenosis.
OBJECTIVES: The authors aimed to compare the diagnostic performance of QFR and the guideline-recommended invasive FFR using 82Rubidium positron emission tomography (82Rb-PET) myocardial perfusion imaging as reference standard.
METHODS: This is a prospective, observational study of symptomatic patients with suspected obstructive coronary artery disease on coronary computed tomography angiography (≥50% diameter stenosis in ≥1 vessel). All patients were referred to 82Rb-PET and invasive coronary angiography with FFR and QFR assessment of all intermediate (30%-90% diameter stenosis) stenoses. Main analyses included a comparison of the ability of QFR and FFR to identify reduced myocardial blood flow (<2 mL/g/min) during vasodilation and/or relative perfusion abnormalities (summed stress score ≥4 in ≥2 adjacent segments).
RESULTS: A total of 250 patients (320 vessels) with indication for invasive physiological assessment were included. The continuous relationship of 82Rb-PET stress myocardial blood flow per 0.10 increase in FFR was +0.14 mL/g/min (95% CI: 0.07-0.21 mL/g/min) and +0.08 mL/g/min (95% CI: 0.02-0.14 mL/g/min) per 0.10 QFR increase. Using 82Rb-PET as reference, QFR and FFR had similar diagnostic performance on both a per-patient level (accuracy: 73%; 95% CI: 67%-79%; vs accuracy: 71%; 95% CI: 64%-78%) and per-vessel level (accuracy: 70%; 95% CI: 64%-75%; vs accuracy: 68%; 95% CI: 62%-73%). The per-vessel feasibility was 84% (95% CI: 80%-88%) for QFR and 88% (95% CI: 85%-92%) for FFR by intention-to-diagnose analysis.
CONCLUSIONS: With 82Rb-PET as reference modality, the wire-free QFR solution showed similar diagnostic accuracy as invasive FFR in evaluation of intermediate coronary stenosis. (DAN-NICAD - Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease; NCT02264717).
引用
- Westra, Rasmussen, Eftekhari, et al. Coronary Artery Stenosis Evaluation by Angiography-Derived FFR: Validation by Positron Emission Tomography and Invasive Thermodilution. JACC Cardiovasc Imaging. 2023. PMID: 37052562. doi:10.1016/j.jcmg.2023.02.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。