文献速递技术与安全CT

按体型分层优化CT患者辐射剂量的有效性

Effectiveness of body size stratification for patient exposure optimization in Computed Tomography.
PubMed 文献 · Eur J Radiol · 2023-03-29

该研究纳入16,933例成人CT体部检查,按水等效直径分为四组,建立体型依赖的诊断参考水平(DRL)。通过混淆矩阵和MCC指标评估,发现体型无关的DRL在小体型和大体型患者中无法识别约20%的次优检查,而体型分层DRL能有效改进剂量优化过程。

要点

  • 体型分层DRL可提高CT剂量优化中对次优检查的识别能力。
  • 体型无关DRL对小体型和大体型患者漏判约20%的次优检查。
  • 建议按水等效直径分组建立DRL以改进剂量管理。
英文原文(摘要)· 点击展开

PURPOSE: To establish size-dependent DRL and to estimate the effectiveness of the size-dependent DRLs over size-independent DRLs for a CT exposure optimization process.

METHODS: The study included 16,933 adult CT body examinations of the most common CT protocols. Acquisitions were included following an image quality assessment. Patients were grouped into five different classes by means of the water equivalent diameter (Dw): 21 ≤ Dw < 25, 25 ≤ Dw < 29, 29 ≤ Dw < 33,33 ≤ Dw < 37 (in cm). CTDIvol, DLP, DLPtot. and SSDE median values were provided both for the sample as a whole (size-independent approach) and for each Dw class (size-dependent approach). The performance of the two approaches in classifying sub-optimal examinations was evaluated through the confusion matrix and Matthews Correlation Coefficient (MCC) metric. The 75th percentile of the CTDIvol distribution was arbitrarily chosen as a threshold level above which the acquisitions are considered sub-optimal.

RESULTS: CTDIvol, DLP, DLPtot and SSDE typical values (median values) are statistically different across Dw groups. The confusion matrix analysis suggests that size-independent DRL could not mark potential suboptimal protocols for small and large patients. The agreement between the size-dependent and size-independent methods is strong only for the most populous classes (MCC > 0.7). For small and large patients size-independent approach fails to identify as sub-optimal around 20 % of the acquisition (MCC≪0.2).

CONCLUSIONS: It was proven by means of the confusion matrix and MCC metric that stratifying DRLs by patient size, size-dependent DRL can be a powerful strategy in order to improve the dose optimization process shown that a size-independent DRL fails to identify sub-optimal examinations for small and large patients.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. De Monte, Sapignoli, Laura Cortinovis, et al. Effectiveness of body size stratification for patient exposure optimization in Computed Tomography. Eur J Radiol. 2023. PMID: 37043885. doi:10.1016/j.ejrad.2023.110804

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。