文献速递心血管CT

冠脉CTA患者特异性触发后延迟的前瞻性验证研究

Patient-specific post-trigger delay in coronary CT angiography: A prospective study comparing with fixed delay.
PubMed 文献 · Eur J Radiol · 2023-04-07

前瞻性随机对照研究纳入204例受试者,比较固定5秒与患者特异性触发后延迟在冠脉CTA中的表现。患者特异性延迟与参考峰值增强时机强相关(R=0.77),可提高冠脉强化程度并改善主观图像质量。

要点

  • 患者特异性触发后延迟可可靠预测峰值增强时机,相关性R=0.77。
  • 该策略使冠脉平均强化较固定延迟提高约33.5 HU。
  • 两名阅片者均认为患者特异性延迟组主观图像质量更优。

核心结论

  • 患者特异性触发后延迟在冠脉CTA中可实现可靠的扫描时机,优化血管充盈并改善图像质量。

研究设计与样本

  • 前瞻性研究将204例连续受试者随机分为固定5秒延迟组(A组,n=102)和患者特异性延迟组(B组,n=102),均采用团注追踪触发。
  • B组同时行测试团注以确定参考峰值增强时机,用于验证预测延迟的准确性和一致性。

诊断标准与关键数值

  • 患者特异性延迟预测值与参考峰值时机的相关系数R=0.77,组内相关系数ICC=0.618。
  • B组各冠状动脉血管平均强化均显著高于A组(均p<0.05),校正个体差异后平均高33.5 HU。
  • 主观图像质量评分B组优于A组(p<0.001)。

临床应用与阅片要点

  • 在冠脉CTA团注追踪方案中,采用患者特异性延迟可改善冠脉强化程度和图像质量。
  • 预测延迟与参考峰值时机呈强相关但一致性中等(ICC=0.618),提示个体化延迟仍有优化空间。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To validate the peak enhancement timing of a patient-specific post-trigger delay (PTD) in Coronary CT angiography (CCTA) and compare its image quality against a fixed PTD.

METHODS: In this prospective study, 204 consecutive participants were randomly divided into two groups to perform CCTA in bolus tracking with either a fixed 5-second PTD (Group A) or a patient-specific PTD (Group B). Test bolus was also performed in Group B to determine the reference peak enhancement timing. One reader evaluated objective image quality, while two readers rated subjective image quality. The predicted PTD was validated through correlation and agreement analysis with the reference measurement. Objective image quality was compared between groups via two-sample t-test and linear regression, while the subjective ratings were compared with chi-square analysis.

RESULTS: The two groups each had 102 participants with comparable characteristics (52.9 ± 11.3 versus 52.1 ± 11.3 years of age, and 53 versus 52 males). The scan timing from patient-specific PTD demonstrated strong correlation (R = 0.77) and consistency (ICC = 0.618) with the reference peak timing. Both readers rated better subjective image quality for the Group B (p < 0.001). The mean vessel enhancement was significantly higher in Group B in all coronary vessels (all p < 0.05). After adjusting for the participant variation, the patient-specific PTD strategy was associated with an average of 33.5 HU higher enhancement compared to the fixed PTD.

CONCLUSIONS: Patient-specific delay could achieve reliable scan timing, optimize vessel opacification and obtain better image quality in CCTA.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Yuan, Wang, Lin, et al. Patient-specific post-trigger delay in coronary CT angiography: A prospective study comparing with fixed delay. Eur J Radiol. 2023. PMID: 37043884. doi:10.1016/j.ejrad.2023.110813

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。