美国乳腺筛查数字乳腺断层摄影的国家性能基准:乳腺癌症监测联盟更新
研究建立了DBT筛查的性能基准,包括异常解读率8.3%、癌症检出率5.8/1000、敏感度87.4%、特异度92.2%、假阴性率0.8/1000。与同期DM相比,DBT除敏感度和假阴性率相似外,其他性能指标均更高;大多数放射科医生达到可接受的性能范围。
要点
- DBT筛查的异常解读率基准为8.3%,癌症检出率5.8/1000。
- DBT敏感度87.4%,特异度92.2%,与DM相比敏感度相似。
- 97.6%的放射科医生癌症检出率达到可接受范围。
局限性
- 回顾性研究设计。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background It is important to establish screening mammography performance benchmarks for quality improvement efforts. Purpose To establish performance benchmarks for digital breast tomosynthesis (DBT) screening and evaluate performance trends over time in U.S. community practice. Materials and Methods In this retrospective study, DBT screening examinations were collected from five Breast Cancer Surveillance Consortium (BCSC) registries between 2011 and 2018. Performance measures included abnormal interpretation rate (AIR), cancer detection rate (CDR), sensitivity, specificity, and false-negative rate (FNR) and were calculated based on the American College of Radiology Breast Imaging Reporting and Data System, fifth edition, and compared with concurrent BCSC DM screening examinations, previously published BCSC and National Mammography Database benchmarks, and expert opinion acceptable performance ranges. Benchmarks were derived from the distribution of performance measures across radiologists (n = 84 or n = 73 depending on metric) and were presented as percentiles. Results A total of 896 101 women undergoing 2 301 766 screening examinations (458 175 DBT examinations [median age, 58 years; age range, 18-111 years] and 1 843 591 DM examinations [median age, 58 years; age range, 18-109 years]) were included in this study. DBT screening performance measures were as follows: AIR, 8.3% (95% CI: 7.5, 9.3); CDR per 1000 screens, 5.8 (95% CI: 5.4, 6.1); sensitivity, 87.4% (95% CI: 85.2, 89.4); specificity, 92.2% (95% CI: 91.3, 93.0); and FNR per 1000 screens, 0.8 (95% CI: 0.7, 1.0). When compared with BCSC DM screening examinations from the same time period and previously published BCSC and National Mammography Database performance benchmarks, all performance measures were higher for DBT except sensitivity and FNR, which were similar to concurrent and prior DM performance measures. The following proportions of radiologists achieved acceptable performance ranges with DBT: 97.6% for CDR, 91.8% for sensitivity, 75.0% for AIR, and 74.0% for specificity. Conclusion In U.S. community practice, large proportions of radiologists met acceptable performance ranges for screening performance metrics with DBT. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Lee and Moy in this issue.
引用
- Lee, Abraham, Miglioretti, et al. National Performance Benchmarks for Screening Digital Breast Tomosynthesis: Update from the Breast Cancer Surveillance Consortium. Radiology. 2023. PMID: 37039687. doi:10.1148/radiol.222499
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。