文献速递心血管US

超声心动图不同步性指标预测电学特征不佳心衰患者的CRT反应

Dyssynchrony and Response to Cardiac Resynchronization Therapy in Heart Failure Patients With Unfavorable Electrical Characteristics.
PubMed 文献 · JACC Cardiovasc Imaging · 2023-03-08

本研究纳入121例电学特征不佳的心衰患者,用斑点追踪超声评估机械不同步性。整体浪费功≥200 mmHg%和间隔收缩模式1/2与CRT反应独立相关,两项标准均阳性者生存率更高,缺乏任一标准则死亡或心衰住院风险显著增加。

要点

  • 整体浪费功≥200 mmHg%和间隔收缩模式1/2可预测CRT反应。
  • 两项标准均阳性者无死亡或心衰住院生存率87%,均阴性仅27%。
  • 缺乏任一标准与死亡/心衰住院风险增加近5倍独立相关。

核心结论

  • 在电学特征不佳的心衰患者中,超声评估机械不同步性有助于筛选可从CRT获益的患者。

研究设计与样本

  • 多中心前瞻性研究纳入551例接受CRT患者中的121例电学特征不佳者,用电斑点追踪超声评估机械不同步性,参考标准为9个月CRT反应和随访死亡/心衰住院。

关键影像表现/征象

  • 评估的机械不同步指标包括间隔闪烁、心尖摇摆、间隔形变模式和整体浪费功。
  • 间隔纵向应变收缩模式1和2与CRT反应独立相关。

诊断标准与关键数值

  • CRT反应定义为术后9个月随访时左室收缩末期容积相对下降≥15%。
  • 整体浪费功≥200 mmHg%与CRT反应相关,校正OR 4.17(95%CI 1.33-14.56),P=0.0182。
  • 间隔纵向应变收缩模式1和2与CRT反应相关,校正OR 10.05(95%CI 2.82-43.97),P<0.001。
  • 缺乏任一标准与死亡和/或心衰住院风险增加相关,校正HR 4.83(95%CI 1.84-12.68),P=0.001。

临床应用与阅片要点

  • 对电学特征不佳的CRT候选者,应重点评估整体浪费功和间隔收缩模式以辅助筛选应答者。
  • 两项标准均阳性者预后较好,均阴性者风险高,报告时应明确描述。

局限性

  • 样本量较小(121例),仅针对电学特征不佳亚组,结论外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Among heart failure (HF) patients undergoing cardiac resynchronization therapy (CRT), those with unfavorable electrical characteristics (UEC) are less frequently CRT responders.

OBJECTIVES: In this study, the authors sought to evaluate the relationship between preprocedural echocardiographic parameters of electromechanical dyssynchrony (EMD) and outcome following CRT.

METHODS: Among 551 patients receiving CRT, 121 with UEC, defined as atypical left bundle branch, presence of right bundle branch block, or unspecified intraventricular conduction disturbance, were enrolled. Indices of EMD were presence of septal flash, apical rocking, septal deformation patterns, and global wasted work (GWW), determined with the use of speckle-tracking strain echocardiography. Endpoints were response to CRT, defined as a relative decrease in left ventricular end-systolic volume ≥15% at 9-month postoperative follow-up, and all-cause death or HF hospitalization during follow-up.

RESULTS: Among the 121 patients, 68 (56%) were CRT responders. In multivariate analysis, GWW ≥200 mm Hg% (adjusted odds ratio [aOR]: 4.17 [95% CI: 1.33-14.56]; P = 0.0182) and longitudinal strain septal contraction patterns 1 and 2 (aOR: 10.05 [95% CI: 2.82-43.97]; P < 0.001) were associated with CRT response. During a 46-month follow-up (IQR: 42-55 months), survival free from death or HF hospitalization increased with the number of positive criteria (87% for 2, 59% for 1, and 27% for 0). After adjustment for established predictors of outcome in patients receiving CRT, absence of either of the 2 criteria remained associated with a considerable increased risk of death and/or HF hospitalization (adjusted HR: 4.83 [95% CI: 1.84-12.68]; P = 0.001).

CONCLUSIONS: In patients with UEC, echocardiographic assessment of EMD may help to select patients who will derive benefit from CRT. (Echocardiography in Cardiac Resynchronization Therapy [Echo-CRT]; NCT02986633).

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Layec, Decroocq, Delelis, et al. Dyssynchrony and Response to Cardiac Resynchronization Therapy in Heart Failure Patients With Unfavorable Electrical Characteristics. JACC Cardiovasc Imaging. 2023. PMID: 37038875. doi:10.1016/j.jcmg.2022.12.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。