文献速递妇产影像US

超声造影参数在O-RADS超声4-5类附件肿块评估中的价值

Value of Contrast-Enhanced Ultrasound Parameters in the Evaluation of Adnexal Masses with Ovarian-Adnexal Reporting and Data System Ultrasound.
PubMed 文献 · Ultrasound Med Biol · 2023-04-07

本研究回顾性分析2020年1-8月接受常规超声和超声造影(CEUS)的附件肿块患者,按O-RADS系统分类。分析CEUS中肿块壁/分隔增强的初始时间和强度(与子宫肌层比较)及内部成分增强征象。ROC曲线显示最佳截断值高于O-RADS 4类。将增强范围信息用于选择性上调O-RADS 4类和下调5类后,总体敏感度提高至90.2%,特异度(91.3%)保持不变。

要点

  • CEUS增强范围信息可选择性上调O-RADS 4类、下调5类,提高敏感度。
  • 调整后总体敏感度升至90.2%,特异度保持91.3%不变。
  • CEUS评估包括肿块壁/分隔增强初始时间和强度,与子宫肌层比较。

关键影像表现/征象

  • CEUS分析中比较肿块壁和/或分隔增强的初始时间及强度与子宫肌层。
  • 观察每个肿块内部成分的增强征象。

诊断标准与关键数值

  • ROC曲线分析显示最佳截断值高于O-RADS 4类。
  • 应用增强范围信息选择性上调O-RADS 4类、下调O-RADS 5类后,总体敏感度增至90.2%,特异度保持91.3%。

临床应用与阅片要点

  • 对O-RADS 4类肿块,若CEUS显示增强范围信息符合上调标准,可考虑升级以提高检出。
  • 对O-RADS 5类肿块,若CEUS增强范围信息支持下调,可避免过度诊断。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The aim of this study was to determine whether incorporating qualitative parameters of contrast-enhanced ultrasound (CEUS) can increase the accuracy of adnexal lesion assessments with Ovarian-Adnexal Reporting and Data System (O-RADS) ultrasound category 4 or 5.

METHODS: Retrospective analysis of patients with adnexal masses who underwent conventional ultrasound (US) and contrast-enhanced ultrasound (CEUS) examinations between January and August of 2020. The study investigators reviewed and analyzed the morphological features of each mass before categorizing the US images independently according to the O-RADS system published by the American College of Radiology. In the CEUS analysis, the initial time and intensity of enhancement involving the wall and/or septation of the mass were compared with the uterine myometrium. Internal components of each mass were observed for signs of enhancement. The sensitivity, specificity, and Youden's index were calculated as the contrast variables and O-RADS.

RESULTS: Receiver operating characteristic curve analysis revealed that the best cutoff value was higher than O-RADS 4. When information on the extent of enhancement was applied to selectively upgrade O-RADS category 4 and selectively downgrade O-RADS category 5, the overall sensitivity increased to 90.2%, while the level of specificity (91.3%) remained the same.

CONCLUSION: Incorporating additional information from CEUS with respect to the extent of enhancement helped to improve the sensitivity of O-RADS category 4 and 5 masses without loss of specificity.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Xu, Huang, Zeng, et al. Value of Contrast-Enhanced Ultrasound Parameters in the Evaluation of Adnexal Masses with Ovarian-Adnexal Reporting and Data System Ultrasound. Ultrasound Med Biol. 2023. PMID: 37032238. doi:10.1016/j.ultrasmedbio.2023.02.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。