文献速递泌尿生殖MR

3.0T 睾丸读出分段扩散加权成像与单次激发平面回波成像的比较

Readout-segmented diffusion weighted imaging of the testis at 3.0 T: comparison with single-shot echo-planar imaging.
PubMed 文献 · Abdom Radiol (NY) · 2023-04-08

该回顾性研究纳入 66 例因不同临床指征行阴囊 MRI 的患者,比较读出分段平面回波成像(RS-EPI)与单次激发平面回波成像(SS-EPI)在睾丸扩散加权成像中的图像质量和表观扩散系数(ADC)值。结果显示 RS-EPI 在几何变形、磁敏感伪影和病灶显示清晰度方面优于 SS-EPI,且两种序列测得的平均 ADC 值高度相关且一致;RS-EPI 测得的平均、最大和最小 ADC 值在正常睾丸实质、良性及恶性睾丸内病变间存在显著差异。

要点

  • RS-EPI 睾丸 DWI 图像质量优于 SS-EPI,几何变形和磁敏感伪影更轻,病灶显示更清晰。
  • RS-EPI 与 SS-EPI 测得的平均 ADC 值高度相关且一致,RS-EPI 具有可行性。
  • RS-EPI 的平均、最大和最小 ADC 值在正常睾丸实质、良性及恶性睾丸内病变间有显著差异。

关键影像表现/征象

  • RS-EPI 图像质量评估显示轻度几何变形和磁敏感伪影,病灶显示清晰度好。
  • 对比图像质量评估显示 SS-EPI 有明显几何变形和磁敏感伪影,RS-EPI 在病灶显示清晰度上更受偏好。
  • RS-EPI 测量的平均、最大和最小 ADC 值在正常睾丸实质、良性及恶性睾丸内病变间存在显著差异。

诊断标准与关键数值

  • RS-EPI 图像质量评分从 1 分(严重变形或伪影,或无法诊断)到 4 分(几乎无变形或伪影,或优秀)。
  • 对比图像质量评分从 -2 分(SS-EPI 严重或更明显)到 2 分(RS-EPI 严重或更明显)。
  • 三位读片者对 RS-EPI 改善图像质量的偏好比例置信区间(CIOP)范围为 97% 至 100%,P < 0.001。

临床应用与阅片要点

  • 在睾丸 DWI 中可优先考虑使用 RS-EPI 以减少几何变形和磁敏感伪影,提高病灶显示清晰度。
  • RS-EPI 与 SS-EPI 测得的平均 ADC 值高度一致,可在临床中互换参考。
  • 注意 RS-EPI 测得的平均、最大和最小 ADC 值在正常睾丸实质、良性及恶性病变间存在差异,可用于辅助鉴别。

局限性

  • 回顾性研究设计。
  • 单中心研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The current study aimed to explore the feasibility of readout-segmented echo-planar imaging (RS-EPI) of the testis at 3.0 T, by comparing with single-shot echo-planar imaging (SS-EPI) in qualitative image quality and quantitative apparent diffusion coefficient (ADC) values.

METHODS: 66 patients undergoing scrotal MRI for various clinical indications were included retrospectively. RS-EPI image quality was rated from 1 (severe distortion or artifact, or nondiagnostic) to 4 (nearly no distortion or artifact, or outstanding). The comparative image quality (RS- vs. SS-EPI) was rated from - 2 (SS-EPI severe or greater conspicuity) to 2 (RS-EPI severe or greater conspicuity). The confidence interval of proportions (CIOP) of comparative image quality and Wilcoxon rank sum test were performed to assess the preferences between RS-EPI and SS-EPI. Paired samples t-test and Bland-Altman analysis were performed to compare the mean ADC values of RS-EPI and SS-EPI. The mean, maximum, and minimum ADC values measured by RS-EPI were compared in normal testicular parenchyma, benign and malignant intratesticular lesions.

RESULTS: The evaluation of RS-EPI image quality showed RS-EPI with the characteristics of slight geometric distortion and susceptibility artifact, and good lesion conspicuity. The assessment of comparative image quality showed SS-EPI with obvious geometric distortion and susceptibility artifact, and RS-EPI preferred in lesion conspicuity. The CIOP ranged from 97 to 100% among three readers, with preferring to RS-EPI improving image quality (P < 0.001). There was a strong correlation and good agreement between mean ADC values measured by RS-EPI and SS-EPI. The mean, maximum and minimum ADC values by RS-EPI were significantly different in normal testicular parenchyma, benign and malignant intratesticular lesions.

CONCLUSION: RS-EPI DWI of the testis improved image quality in geometric distortion, susceptibility artifacts, and lesion conspicuity, and provided highly correlated and consistent mean ADC values when compared to SS-EPI DWI, indicating the feasibility of RS-EPI DWI of testes.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Yao, Huang, Li, et al. Readout-segmented diffusion weighted imaging of the testis at 3.0 T: comparison with single-shot echo-planar imaging. Abdom Radiol (NY). 2023. PMID: 37029814. doi:10.1007/s00261-023-03899-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。