PubMed 文献 · Eur Radiol · 2023-04-06

结果显示μQFR与相对TTP、MTT相关,以0.82为界诊断低灌注的敏感度94.1%、特异度92.1%;治疗后μQFR、侧支评分和吸烟状态与灌注改善独立相关。

要点

  • μQFR与CTP参数相关,可辅助实时评估颅内狭窄血流动力学。
  • μQFR≤0.82提示低灌注,敏感度94.1%、特异度92.1%。
  • 治疗后μQFR、侧支评分和吸烟状态与灌注改善独立相关。

核心结论

  • 在症状性前循环颅内动脉粥样硬化性狭窄患者中,μQFR与CT灌注参数相关,可能作为介入过程中实时血流动力学评估的潜在标志物。

研究设计与样本

  • 基于单一体位血管造影计算Murray定律QFR(μQFR),并计算CT灌注参数(CBF、CBV、MTT、TTP)及症状侧与对侧半球比值。

诊断标准与关键数值

  • μQFR以0.82为界诊断低灌注的敏感度为94.1%、特异度为92.1%。
  • μQFR与相对TTP和相对MTT呈负相关:基于患者的相关系数分别为-0.45和-0.26,基于血管的相关系数分别为-0.72和-0.43(均p<0.05)。
  • 多因素分析显示μQFRpost(调整OR=1.48,p=0.002)、侧支评分(调整OR=6.97,p=0.01)和当前吸烟状态(调整OR=0.03,p=0.01)与治疗后灌注改善独立相关。

临床应用与阅片要点

  • μQFR可在介入过程中实时评估血流动力学,辅助判断狭窄的功能意义。
  • μQFR≤0.82可作为提示低灌注的参考阈值,需结合CT灌注参数综合判断。
  • 治疗后μQFR、侧支评分和吸烟状态有助于预测灌注改善。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Cerebral hemodynamics is important for the management of intracranial atherosclerotic stenosis (ICAS). This study aimed to determine the utility of angiography-based quantitative flow ratio (QFR) to reflect cerebral hemodynamics in symptomatic anterior circulation ICAS by evaluating its association with CT perfusion (CTP).

METHODS: Sixty-two patients with unilateral symptomatic stenosis in the intracranial internal carotid artery or middle cerebral artery who received percutaneous transluminal angioplasty (PTA) or PTA with stenting were included. Murray law-based QFR (μQFR) was computed from a single angiographic view. CTP parameters including cerebral blood flow, cerebral blood volume, mean transit time (MTT), and time to peak (TTP) were calculated, and relative values were obtained as the ratio between symptomatic and contralateral hemispheres. Relationships between μQFR and perfusion parameters, and between μQFR and perfusion response after intervention, were analyzed.

RESULTS: Thirty-eight patients had improved perfusion after treatment. μQFR was significantly correlated with relative values of TTP and MTT, with correlation coefficients of -0.45 and -0.26, respectively, on a per-patient basis, and -0.72 and -0.43, respectively, on a per-vessel basis (all p < 0.05). Sensitivity and specificity for μQFR to diagnose hypoperfusion at a cut-off value of 0.82 were 94.1% and 92.1%, respectively. Multivariate analysis revealed that μQFRpost (adjusted odds ratio [OR], 1.48; p = 0.002), collateral score (adjusted OR, 6.97; p = 0.01), and current smoking status (adjusted OR, 0.03; p = 0.01) were independently associated with perfusion improvement after treatment.

CONCLUSIONS: μQFR was associated with CTP in patients with symptomatic anterior circulation ICAS and may be a potential marker for real-time hemodynamic evaluation during interventional procedures.

KEY POINTS: • Murray law-based QFR (μQFR) is associated with CT perfusion parameters in intracranial atherosclerotic stenosis and can differentiate hypoperfusion from normal perfusion. • Post-intervention μQFR, collateral score, and current smoking status are independent factors associated with improved perfusion after treatment.

来源:Eur Radiol,查看原文。版权归原作者所有。