无创针与切割针在透视引导腰椎穿刺中的比较
单中心回顾性病例对照研究比较无创针与切割针在透视引导腰椎穿刺中的操作难度,以透视时间和剂量面积乘积(DAP)为替代指标。结果显示两组透视时间、DAP及平均尝试次数均无显著差异,提示无创针不增加操作难度,鉴于其较低并发症率应考虑使用。
要点
- 透视引导腰椎穿刺使用无创针不增加透视时间、辐射剂量或尝试次数。
- 无创针可降低穿刺后并发症,透视引导下也应优先考虑。
- 操作难度替代指标为透视时间和DAP,两者组间无显著差异。
局限性
- 单中心回顾性设计
- 以透视时间和DAP为操作难度的替代指标
- 政策改变后组有3例初始无创针失败后改用切割针
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Atraumatic needles are known to reduce complication rates of blind lumbar punctures (LP), however, their use in fluoroscopically guided LP is less studied. This study assessed the comparative difficulty of performing fluoroscopic lumbar puncture with atraumatic needles.
METHODS: Single-centre retrospective case-control study comparing atraumatic and conventional or "cutting" needles using fluoroscopic time and radiation dose (Dose Area Product or DAP) as surrogate markers. Patients were assessed from two comparable eight-month periods before and after a policy change to primary use of atraumatic needles.
RESULTS: 105 procedures with a cutting needle were performed in the group prior to the policy change. Median fluoroscopy time was 48 sec and median DAP was 3.14. Of 102 procedures performed in the group after the policy change, 99 were performed with an atraumatic needle and three with a cutting needle after initial attempt with an atraumatic needle. Median fluoroscopy time was 41 sec and median DAP was 3.28. The mean number of attempts was 1.02 in the cutting needle group and 1.05 in the atraumatic needle group. There was no significant difference in median fluoroscopy time, median DAP, or mean number of attempts.
CONCLUSION: Fluoroscopic screening time, DAP and mean number of attempts were not significantly increased with primary use of atraumatic needles for LP. Use of atraumatic needles should be considered in fluoroscopic LP given the lower complication rates.
ADVANCES IN KNOWLEDGE: This study provides new data showing that the use of atraumatic needles does not increase the difficulty of fluoroscopically guided LP.
引用
- Lee, Clements, Lukies, et al. Atraumatic versus cutting needles in fluoroscopic lumbar puncture. Br J Radiol. 2023. PMID: 37017612. doi:10.1259/bjr.20220993
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。