文献速递腹部CTMR

胰腺CT脂肪分数全自动全容积测量与Dixon MR成像的相关性

Automated whole-volume measurement of CT fat fraction of the pancreas: correlation with Dixon MR imaging.
PubMed 文献 · Br J Radiol · 2023-04-22

结果显示-30 HU、-20 HU和-10 HU阈值的CT-FVF均与MR-FVF呈显著正相关(ρ=0.898、0.905、0.909,p<0.001),其中-20 HU阈值的CT-FVF与MR-FVF一致性合理,平均绝对固定偏差为0.32%。结论提示-20 HU阈值的CT-FVF可能是一种可行、无创且便捷的胰腺脂肪变性定量技术。

要点

  • 平扫CT以-20 HU为阈值自动全容积测量胰腺脂肪分数与MR-PDFF相关性好且偏差低。
  • CT-FVF与MR-FVF呈显著正相关,-20 HU阈值一致性最佳。
  • 该方法为胰腺脂肪变性提供无创便捷的定量手段。

核心结论

  • 基于-20 HU阈值的胰腺CT脂肪分数全自动全容积测量与MR-PDFF相关性好且一致性合理,可能是一种可行、无创且便捷的胰腺脂肪变性定量技术。

研究设计与样本

  • CT采用平扫,通过直方图分析结合局部阈值法自动全容积测量胰腺脂肪体积分数(CT-FVF)。
  • MRI采用质子密度脂肪分数(PDFF)技术测量MR-FVF作为参考。
  • 比较-30 HU、-20 HU和-10 HU三种CT阈值下的CT-FVF与MR-FVF的相关性和一致性。

诊断标准与关键数值

  • 胰腺-30 HU CT-FVF中位值8.6%(IQR 11.3),-20 HU CT-FVF中位值10.5%(IQR 13.2),-10 HU CT-FVF中位值13.4%(IQR 16.1),MR-FVF中位值10.9%(IQR 9.7)。
  • -30 HU、-20 HU和-10 HU CT-FVF与MR-FVF的相关系数分别为ρ=0.898(p<0.001)、ρ=0.905(p<0.001)、ρ=0.909(p<0.001)。
  • -20 HU CT-FVF与MR-FVF的平均绝对固定偏差为0.32%,一致性界限为-10.1%至10.7%。

临床应用与阅片要点

  • 日常阅片可关注平扫CT上胰腺脂肪浸润,-20 HU阈值下自动全容积测量与MR-PDFF一致性较好。
  • 注意CT阈值选择影响脂肪分数绝对值,报告时需注明所用阈值。

局限性

  • 未报告CT与MRI扫描间隔时间,可能影响一致性评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to assess the feasibility of pancreatic steatosis quantification by automated whole-volume measurement of the fat fraction of the pancreas on CT in comparison to MRI using proton-density fat fraction (PDFF) techniques.

METHODS: Fifty-nine patients who underwent both CT and MRI were analyzed. Automated whole-volume measurement of pancreatic fat on unenhanced CT was performed by a histogram analysis with local thresholding. Three sets of CT fat volume fraction (FVF) (%) values with thresholds of -30 Hounsfield unit (HU), -20 HU and -10 HU were compared to MR-FVF (%) values measured on a PDFF map.

RESULTS: The median -30 HU CT-FVF, -20 HU CT-FVF, -10 HU CT-FVF and MR-FVF values of the pancreas were 8.6% (interquartile range (IQR), 11.3), 10.5% (IQR, 13.2), 13.4% (IQR, 16.1) and 10.9% (IQR, 9.7), respectively. The -30 HU CT-FVF (%), -20 HU CT-FVF (%) and -10 HU CT-FVF (%) of the pancreas showed a significant positive correlation with the MR-FVF (%) of the pancreas (ρ = 0.898, p < 0.001, ρ = 0.905, p < 0.001, ρ = 0.909, p < 0.001, respectively). The -20 HU CT-FVF (%) displayed reasonable agreement with the MR-FVF (%) with a low absolute fixed bias (mean difference, 0.32%; limit of agreement from -10.1 to 10.7%).

CONCLUSION: The automated whole-volume measurement of the CT fat fraction of the pancreas using the threshold CT attenuation value of -20 HU may be a feasible, non-invasive, and convenient technique for quantifying pancreatic steatosis.

ADVANCES IN KNOWLEDGE: CT-FVF value of the pancreas had a positive correlation with the MR-FVF value. The -20 HU CT-FVF may be a convenient technique for quantifying pancreatic steatosis.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Tanabe, Higashi, Tanabe, et al. Automated whole-volume measurement of CT fat fraction of the pancreas: correlation with Dixon MR imaging. Br J Radiol. 2023. PMID: 37017644. doi:10.1259/bjr.20220937

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。