文献速递胸部心血管CT

基于人工智能的超低剂量CT去噪方法用于肺癌筛查

A Novel Artificial Intelligence Based Denoising Method for Ultra-Low Dose CT Used for Lung Cancer Screening.
PubMed 文献 · Acad Radiol · 2023-04-03

该前瞻性研究纳入123例患者,评估超低剂量CT及AI去噪重建(dULD)在肺癌筛查中的表现。ULD平均辐射剂量降低76%(48%-85%),dULD与低剂量CT在阴性/可操作Lung-RADS分类上无差异,且dULD阴性似然比更优(0.021-0.051),对冠状动脉钙化检测敏感度高(93.9%-97.6%),读者间一致性几乎完美。

要点

  • AI去噪超低剂量CT可降低辐射剂量76%而不影响Lung-RADS分类判读。
  • dULD对冠状动脉钙化的敏感度达93.9%-97.6%,准确率91.7%。
  • dULD阴性似然比0.021-0.051,优于ULD的0.033-0.097。

关键影像表现/征象

  • dULD扫描中88例(74%)和81例(68%)患者检出冠状动脉钙化,ULD扫描中分别为74例(62.2%)和77例(64.7%)。
  • 读者间对冠状动脉钙化评分的一致性:LD扫描ICC=0.924,dULD扫描ICC=0.903,ULD扫描ICC=0.817。

诊断标准与关键数值

  • ULD平均辐射剂量降低76%(范围48%-85%)。
  • dULD与LD在阴性与可操作Lung-RADS分类比较无差异(p=0.22 RE,p>0.999 RR);ULD与LD亦无差异(p=0.75 RE,p>0.999 RR)。
  • ULD读者阴性似然比为0.033-0.097,dULD为0.021-0.051。
  • dULD检测冠状动脉钙化的敏感度为93.9%-97.6%,准确率91.7%。

临床应用与阅片要点

  • AI去噪后的超低剂量CT图像可用于肺癌筛查,不影响可操作肺结节和主动脉瘤等关键发现的判读。
  • dULD图像上冠状动脉钙化检出率高于ULD,且读者间一致性高,可辅助心血管风险评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To assess ultra-low-dose (ULD) computed tomography as well as a novel artificial intelligence-based reconstruction denoising method for ULD (dULD) in screening for lung cancer.

MATERIALS AND METHODS: This prospective study included 123 patients, 84 (70.6%) men, mean age 62.6 ± 5.35 (55-75), who had a low dose and an ULD scan. A fully convolutional-network, trained using a unique perceptual loss was used for denoising. The network used for the extraction of the perceptual features was trained in an unsupervised manner on the data itself by denoising stacked auto-encoders. The perceptual features were a combination of feature maps taken from different layers of the network, instead of using a single layer for training. Two readers independently reviewed all sets of images.

RESULTS: ULD decreased average radiation-dose by 76% (48%-85%). When comparing negative and actionable Lung-RADS categories, there was no difference between dULD and LD (p = 0.22 RE, p > 0.999 RR) nor between ULD and LD scans (p = 0.75 RE, p > 0.999 RR). ULD negative likelihood ratio (LR) for the readers was 0.033-0.097. dULD performed better with a negative LR of 0.021-0.051. Coronary artery calcifications (CAC) were documented on the dULD scan in 88(74%) and 81(68%) patients, and on the ULD in 74(62.2%) and 77(64.7%) patients. The dULD demonstrated high sensitivity, 93.9%-97.6%, with an accuracy of 91.7%. An almost perfect agreement between readers was noted for CAC scores: for LD (ICC = 0.924), dULD (ICC = 0.903), and for ULD (ICC = 0.817) scans.

CONCLUSION: A novel AI-based denoising method allows a substantial decrease in radiation dose, without misinterpretation of actionable pulmonary nodules or life-threatening findings such as aortic aneurysms.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Gorenstein, Onn, Green, et al. A Novel Artificial Intelligence Based Denoising Method for Ultra-Low Dose CT Used for Lung Cancer Screening. Acad Radiol. 2023. PMID: 37019699. doi:10.1016/j.acra.2023.02.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。