零回波时间MRI在肩关节MRI方案中诊断肩袖钙化性肌腱病:较常规MRI序列提高钙化灶识别,但仍逊于X线平片
回顾性研究纳入46例肩袖钙化性肌腱病(RCCT)患者和51例对照,比较标准MRI与标准MRI+零回波时间(ZTE)序列对钙化灶的检测效能,以计算机X线摄影(CR)为参考标准。结果显示,加入ZTE后,两位阅片者的敏感度分别从57.4%和47.5%提升至77%和75.4%,特异度相近(96.6%-98.7%)。但ZTE仍存在较高频率的伪影(关节积液、肱二头肌长头腱、肩峰下囊呈高信号),且钙化检出率受疾病分期影响(钙化期达100%,吸收期最高80.7%)。
要点
- 肩关节MRI中加入ZTE序列可提高RCCT钙化灶的检出敏感度,但仍有约半数常规MRI未见的钙化ZTE亦未显示。
- ZTE图像上关节积液、肱二头肌长头腱和肩峰下囊可呈高信号伪影,阅片时需注意与钙化鉴别。
- ZTE对钙化灶的检出率与疾病分期相关,钙化期可达100%,吸收期最高仅80.7%。
关键影像表现/征象
- ZTE图像上关节积液呈高信号伪影,见于62.8%的患者。
- ZTE图像上肱二头肌长头腱呈高信号伪影,见于60.8%的患者。
- ZTE图像上肩峰下囊呈高信号伪影,见于27.8%的患者。
诊断标准与关键数值
- 以MRI+CR为参考标准,标准MRI+ZTE检测钙化沉积的敏感度:阅片者1为77%(95% CI: 64.5-86.8),阅片者2为75.4%(95% CI: 62.7-85.5)。
- 标准MRI检测钙化沉积的敏感度:阅片者1为57.4%(95% CI: 44.1-70),阅片者2为47.5%(95% CI: 34.6-60.7)。
- 两种技术(标准MRI和标准MRI+ZTE)的特异度相近,范围为96.6%(95% CI: 93.3-98.5)至98.7%(95% CI: 96.3-99.7)。
- ZTE对钙化灶的检出率依赖于疾病分期:钙化期达100%,吸收期最高为80.7%。
临床应用与阅片要点
- 在肩关节MRI方案中加入ZTE序列有助于提高钙化性肌腱病的检出,尤其对常规序列未显示的钙化。
- 阅片时需注意ZTE图像上关节积液、肱二头肌长头腱和肩峰下囊的高信号伪影,避免误诊为钙化。
- ZTE对吸收期钙化的检出率有限,阴性结果不能完全排除钙化,必要时结合X线平片。
局限性
- 回顾性研究设计。
- 样本量有限(46例RCCT和51例对照)。
- 原文未明确报告其他局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare the diagnostic performance of standard MRI and standard MRI + ZTE images for the detection of rotator cuff calcific tendinopathy (RCCT) and to describe the artifacts encountered with ZTE images, using computed radiography (CR) as a reference.
METHODS: In a retrospective study, patients with suspicion of rotator cuff tendinopathy who underwent standard MRI + ZTE images after radiography were enrolled between June 2021 and June 2022. Images were independently analyzed for calcific deposit presence and ZTE images artifacts, by two radiologists. Diagnostic performance was calculated individually with MRI + CR as the reference standard.
RESULTS: A total of 46 RCCT subjects (27 women; mean age, 55.3 years ± 12.4) and 51 control subjects (27 men; mean age, 45.5 ± 12.9) were evaluated. For both readers, there was an increase in the sensitivity for the identification of calcific deposits of MRI + ZTE compared to MRI (77% (95% CI: 64.5-86.8) and 75.4% (95% CI: 62.7-85.5) versus 57.4% (95% IC: 44.1-70) and 47.5% (95% IC: 34.6-60.7), for R1 and R2, respectively). Specificity was quite similar for both readers and both imaging techniques and ranged from 96.6% (95% IC: 93.3-98.5) to 98.7% (95% IC: 96.3-99.7). Hyperintense joint fluid (62.8% of patients), long head of the biceps tendon (in 60.8%), and subacromial bursa (in 27.8%) on ZTE were considered artifactual.
CONCLUSION: The addition of ZTE images to a standard MRI protocol improved MRI diagnostic performance of RCCT, but with a suboptimal detection rate and a relatively high frequency of artifactual soft tissue signal hyperintensity.
KEY POINTS: • Adding ZTE images to standard shoulder MRI improves the MR-based detection of rotator cuff calcific tendinopathy, but half of the calcification unseen with standard MRI remained unseen with ZTE MRI. On ZTE images, joint fluid and long head biceps tendon were hyperintense in about 60% of the shoulders, as well as the subacromial bursa in about 30%, without calcific deposit on conventional radiographs. • The detection rate of calcific deposits using ZTE images was dependent on the disease phase. In the calcific stage, it reached 100% in this study but remained at a maximum of 80.7% in the resorptive phase.
引用
- Puel, Lombard, Hossu, et al. Zero echo time MRI in shoulder MRI protocols for the diagnosis of rotator cuff calcific tendinopathy improves identification of calcific deposits compared to conventional MR sequences but remains sub-optimal compared to radiographs. Eur Radiol. 2023. PMID: 37014406. doi:10.1007/s00330-023-09602-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。