文献速递头颈甲状腺与浅表US

淋巴造影增强超声提升甲状腺癌颈部淋巴结转移诊断

Lymphatic Contrast-enhanced US to Improve the Diagnosis of Cervical Lymph Node Metastasis from Thyroid Cancer.
PubMed 文献 · Radiology · 2023-04-04

单中心前瞻性研究纳入64例疑似甲状腺癌患者共76枚颈部淋巴结,术前分别行B模式超声和经甲状腺注射造影剂的淋巴造影增强超声(LCEUS),以细针穿刺细胞学、洗脱液甲状腺球蛋白或术后病理为参考标准。LCEUS诊断淋巴结转移的敏感度、特异度和准确率分别为97%、90%和93%,均优于常规B模式超声的81%、80%和80%,尤其对小于1 cm的淋巴结和中央区(VI区)淋巴结诊断准确率更高。

要点

  • LCEUS诊断颈部淋巴结转移的准确率93%,优于B模式超声的80%。
  • 对小于1 cm淋巴结,LCEUS准确率95%,显著高于超声的82%。
  • 对中央区(VI区)淋巴结,LCEUS准确率96%,显著高于超声的83%。

局限性

  • 单中心研究
  • 样本量较小(64例患者、76枚淋巴结)

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background The presence of cervical lymph node (LN) metastases (LNMs) affects clinical staging and prognosis of thyroid cancer, but the role of conventional B-mode US is limited for preoperative diagnosis of LNMs. The diagnostic value of lymphatic contrast-enhanced US (LCEUS) in thyroid cancer is still being explored. Purpose To explore the diagnostic performance of LCEUS by means of thyroidal injection of contrast agent in comparison with US in detecting LNMs of suspected thyroid cancer. Materials and Methods In this single-center prospective study conducted from November 2020 to January 2021, consecutive participants with suspected thyroid cancer underwent B-mode US and LCEUS of cervical LNs before biopsy. LNMs were confirmed with fine-needle aspiration cytologic examination, thyroglobulin washout assessment, or histopathologic examination after surgery. The diagnostic performance of LCEUS for cervical LNs was compared with that of conventional B-mode US, and its association with LN size and location was evaluated. Results The final data set included 64 participants (mean age, 45 years ± 12 [SD]; 52 women) with 76 LNs. The sensitivity, specificity, and accuracy of LCEUS for LNM were 97%, 90%, and 93%, respectively, whereas they were 81%, 80%, and 80%, respectively, for LNM at conventional B-mode US. Compared with US, LCEUS had better diagnostic accuracy for the LNs smaller than 1 cm (82% vs 95%; P = .03) and for central neck LNs (level VI) (83% vs 96%; P = .04). Conclusion Lymphatic contrast-enhanced US had better diagnostic performance than conventional B-mode US for detecting cervical LN metastases in suspected thyroid cancer before surgery, especially for LNs smaller than 1 cm and central neck LNs. © RSNA, 2023 See also the editorial by Grant and Kwon in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Zhang, Lu, Li, et al. Lymphatic Contrast-enhanced US to Improve the Diagnosis of Cervical Lymph Node Metastasis from Thyroid Cancer. Radiology. 2023. PMID: 37014243. doi:10.1148/radiol.221265

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。