文献速递泌尿生殖MR

半自动软件在前列腺MRI二次阅读中评估可疑病灶的作用:英国三级转诊中心结果

A semi-automated software program to assess the impact of second reads in prostate MRI for equivocal lesions: results from a UK tertiary referral centre.
PubMed 文献 · Eur J Radiol · 2023-03-24

研究纳入664例在前列腺一站式门诊接受多参数MRI的患者,由7位专家放射科医生用MIM®软件和Likert量表初读,再由另一位专家用定制工作流二次阅读。初读Likert 3分者占31%,二次阅读后61%一致;49%的Likert 3分患者接受了活检,其中30%有临床显著疾病;24%的活检可能被推迟。

要点

  • 初读Likert 3分病灶经二次阅读后约61%保持一致,可减少不确定报告。
  • 结合工作流生成的活检轮廓,约24%的Likert 3分活检可能被推迟。
  • 二次阅读有助于一站式门诊中减少不必要活检及相关副作用。

关键影像表现/征象

  • 初读Likert 3分(可疑)病灶占31%(209/664)。
  • 二次阅读后61%(128/209)的Likert 3分病灶保持 concordant。
  • 49%(103/209)的Likert 3分患者接受了活检,其中30%(31/103)为临床显著疾病(Gleason≥3+4)。

诊断标准与关键数值

  • 临床显著疾病定义为Gleason评分≥3+4。
  • Likert 3分定义为可疑病灶;二次阅读使用工作流生成的活检轮廓进行视觉靶向。
  • 在二次阅读降级且使用工作流轮廓活检的Likert 3分病例中,24%(25/103)的活检可能被推迟。

临床应用与阅片要点

  • 对Likert 3分可疑病灶,建议二次阅读并结合精确轮廓勾画以辅助决策。
  • 利用软件生成的活检轮廓可提高视觉靶向准确性,帮助判断是否可推迟活检。
  • 注意二次阅读仅使61%的Likert 3分病例一致,仍有部分病例需进一步评估。

局限性

  • 单中心回顾性设计,结果外推需谨慎。
  • 仅纳入连续患者,未报告随机化或盲法细节。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the utility of a prostate magnetic resonance imaging (MRI) second read using a semi-automated software program in the one-stop clinic, where patients undergo multiparametric MRI, review and biopsy planning in one visit. We looked at concordance between readers for patients with equivocal scans and the possibility for biopsy deferral in this group.

METHODS: We present data from 664 consecutive patients. Scans were reported by seven different expert genitourinary radiologists using dedicated software (MIM®) and a Likert scale. All scans were rescored by another expert genitourinary radiologist using a customised workflow for second reads that includes annotated biopsy contours for accurate visual targeting. The number of scans in which a biopsy could have been deferred using biopsy results and prostate specific antigen density was assessed. Gleason score ≥ 3 + 4 was considered clinically significant disease. Concordance between first and second reads for equivocal scans (Likert 3) was evaluated.

RESULTS: A total of 209/664 (31%) patients scored Likert 3 on first read, 128 of which (61%) were concordant after second read. 103/209 (49%) of patients with Likert 3 scans were biopsied, with clinically significant disease in 31 (30%) cases. Considering Likert 3 scans that were both downgraded and biopsied using the workflow-generated biopsy contours, 25/103 (24%) biopsies could have been deferred.

CONCLUSIONS: Implementing a semi-automated workflow for accurate lesion contouring and targeting biopsies is helpful during the one-stop clinic. We observed a reduction of indeterminate scans after second reading and almost a quarter of biopsies could have been deferred, reducing the potential biopsy-related side effects.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Woernle, Dickinson, Lelie, et al. A semi-automated software program to assess the impact of second reads in prostate MRI for equivocal lesions: results from a UK tertiary referral centre. Eur J Radiol. 2023. PMID: 37003197. doi:10.1016/j.ejrad.2023.110796

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。