乳腺X线摄影中「无定形」形态微钙化的恶性风险分层:基于BI-RADS第5版的研究
研究纳入367例乳腺X线摄影表现为无定形微钙化并接受手术活检的病例,按点状钙化共存比例分为三组:以点状为主组(A组,无定形<50%)、以无定形为主组(B组,无定形>50%)和纯无定形组(C组,100%无定形)。结论认为纯无定形微钙化适合BI-RADS 4B类,与点状钙化共存时恶性风险降低适合4A类或更低,以点状为主时可考虑随访。
要点
- 纯无定形微钙化(C组)阳性预测值23.3%,适合BI-RADS 4B类。
- 无定形与点状共存时恶性风险降低,以点状为主组阳性预测值仅1.0%。
- 分布方式(弥漫、区域、成簇、线样/段样)阳性预测值无统计学差异。
关键影像表现/征象
- 无定形微钙化按点状共存比例分为三组:以点状为主组(无定形<50%)、以无定形为主组(无定形>50%)、纯无定形组(100%无定形)。
- 分布分类为弥漫、区域、成簇和线样/段样。
诊断标准与关键数值
- 总体阳性预测值为5.2%。
- 分布阳性预测值:弥漫0%、区域4.9%、成簇5.0%、线样/段样11.1%,无统计学差异。
临床应用与阅片要点
- 报告无定形微钙化时应描述是否合并点状钙化及大致比例,以辅助BI-RADS分类。
- 纯无定形微钙化可归为4B类,建议活检。
- 以点状为主的无定形微钙化恶性风险低,可考虑随访而非立即活检。
局限性
- 回顾性研究,仅纳入接受手术活检的病例,可能存在选择偏倚。
- 单中心研究,样本量有限。
- 分布方式的阳性预测值差异无统计学意义,需更大样本验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate the malignant risk stratification of microcalcifications interpreted as amorphous morphology on mammography according to the coexistence of punctate microcalcifications based on the 5th edition of the Breast Imaging Reporting and Data System.
METHOD: Between March 2013 and September 2020, 367 microcalcifications interpreted as amorphous morphology on mammography with surgical biopsies were included. The amorphous microcalcifications were classified into a predominantly punctate group (A, <50% of amorphous), a predominantly amorphous group (B, >50% of amorphous), and an only amorphous group (C, 100% of amorphous). The distribution was classified into diffuse, regional, grouped, and linear/segmental. The reference standard was the pathology. The positive predictive values (PPV) were calculated and compared using the Chi-square's test or Fisher's exact test and Kruskal-Wallis test.
RESULTS: The overall PPV of microcalcifications interpreted as having an amorphous morphology was 5.2%. The PPV across groups significantly increased in proportion to the amorphous morphology, with 1.0% in group A, 5.6% in group B, and 23.3% in group C (p <.001). Furthermore, the PPV between group A and groups B plus C (10.1%) and groups A plus B (2.8%) and group C were significantly different (p <.001). The PPV of distribution was 0% for diffuse, 4.9% for regional, 5.0% for grouped, and 11.1% for linear/segmental distributions, without statistical significance.
CONCLUSIONS: Pure amorphous microcalcifications are suitable for category 4B. However, when they coexist with punctate morphology, the malignant risk decreases suitable for category 4A or lower. When amorphous microcalcifications coexist with a predominantly punctate morphology, follow-up should be considered.
引用
- Kim, Kim, Jung, et al. Assessment of malignant risk stratification for microcalcifications interpreted as "amorphous" morphology on mammography: A study based on the 5th edition of breast Imaging Reporting and Data System. Eur J Radiol. 2023. PMID: 36996721. doi:10.1016/j.ejrad.2023.110795
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。