超短优化MRI协议评分系统预测附件扭转卵巢坏死
回顾性纳入43例附件扭转患者,评估基于T2序列的MRI评分系统预测出血性坏死,并与术中及病理对照。卵巢间质、卵泡周围、囊壁或卵巢包膜及扭转蒂的低信号为预测因子,评分≥2分预测坏死的敏感度92%、特异度83%-94%,读者间一致性最高。优化MRI可作为快速诊断附件扭转并准确预测坏死的单一影像手段。
要点
- T2序列上卵巢间质、卵泡周围、囊壁/包膜及扭转蒂低信号是坏死预测因子。
- 低信号评分≥2分预测出血性坏死的敏感度92%、特异度83%-94%。
- 评分≥2分时读者间一致性最高,可用于快速分诊。
关键影像表现/征象
- 卵巢间质、卵泡周围、囊壁或卵巢包膜及扭转蒂在T2序列上呈低信号为预测坏死的征象。
- 上述低信号及囊壁增厚被作为坏死的预测因子,评分基于阳性征象数目。
诊断标准与关键数值
- 低信号评分≥2分预测出血性坏死:观察者1敏感度92%、特异度89%、PPV 92%、NPV 89%。
- 观察者2敏感度92%、特异度94%、PPV 96%、NPV 90%。
- 观察者3敏感度92%、特异度83%、PPV 89%、NPV 89%。
临床应用与阅片要点
- 对疑似附件扭转患者,可应用T2序列低信号评分≥2分快速提示出血性坏死,辅助临床分诊。
- 注意评估卵巢间质、卵泡周围、囊壁/包膜及扭转蒂的低信号,并关注囊壁增厚。
局限性
- 回顾性研究,样本量较小(43例),未报告多中心验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate a MRI scoring system predicting haemorrhagic necrosis in adnexal torsion with intraoperative and/or histopathological correlation using an abbreviated and optimized MRI protocol.
METHODS: This retrospective observational study includes patients with adnexal torsion who underwent Magnetic Resonance Imaging(MRI) and surgery. T2 sequences were evaluated by three observers of varying experience for following findings: Hypo-intensity of ovarian stroma, around the follicle, cyst wall or ovarian capsule and the twisted pedicle. Hypo-intensities in the above and a thick cyst wall were considered as predictors of necrosis. A scoring system was created based on the number of positive findings. MRI was correlated with intraoperative and histopathological findings. Lesions showing haemorrhagic necrosis were considered true positives.
RESULTS: 43 women with torsion were included. 74.4% were secondary to a lead point and 25.4% were without one. Hypointensity score of 2 or more had the highest diagnostic accuracy and inter-reader agreement in predicting necrosis (R1-sensitivity: 92%, specificity: 89%, positive predictive value (PPV): 92% and negative predictive value (NPV): 89%, R2-sensitivity: 92%, specificity: 94%, PPV: 96% and NPV: 90% and R3-sensitivity: 92%, specificity: 83%, PPV: 89% and NPV: 89%).
CONCLUSION: In patients with suspected adnexal torsion, optimized MRI using T2 weighted sequences will serve as a rapid and effective single imaging modality for diagnosing adnexal torsion and accurately predicting necrosis thereby triaging the patients for appropriate management.
引用
- Renganathan, Subramaniam, Deebika, et al. Scoring system for predicting ovarian necrosis in adnexal torsion using an ultra-short optimized MRI protocol. Abdom Radiol (NY). 2023. PMID: 36988699. doi:10.1007/s00261-023-03886-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。