指南与共识技术与安全CTMRUS

影响门诊影像报告建议依从性的因素

Factors Affecting Adherence to Outpatient Radiology Report Recommendations.
指南 / 共识 · J Am Coll Radiol · 2023-03-27

本研究回顾性分析255份含随访建议的门诊CT、US、MRI报告,发现影像随访执行率为65%。强烈、非条件性建议的依从率更高;直接与开具医生沟通、无癌症病史及未指定随访间隔的建议随访时间更短。

要点

  • 非条件性建议的随访执行率(89.15%)显著高于条件性建议(10.48%)。
  • 强烈措辞建议的随访执行率(83.13%)显著高于非强烈建议(16.86%)。
  • 直接沟通医生可缩短中位随访时间(28天 vs 70天)。

诊断标准与关键数值

  • 影像随访总体执行率65%(166/255)。
  • 非条件性建议执行率89.15%(148/166),条件性建议10.48%(18/166),P=.008。
  • 强烈建议执行率83.13%(138/166),非强烈建议16.86%(28/166),P=.009。
  • 有癌症史者中位随访时间28天 vs 无癌症史82天(P=.00057)。
  • 直接沟通医生者中位随访70天 vs 未沟通28天(P=.0069)。

临床应用与阅片要点

  • 在报告中采用强烈措辞和非条件性随访建议可提高依从性。
  • 直接与开具医生沟通可缩短随访延迟。
  • 指定具体随访间隔需权衡其对随访时间的影响。

局限性

  • 回顾性单中心研究,样本量255份报告。
  • 仅纳入含关键词的门诊报告,排除急诊、住院及常规监测建议。
  • 未评估患者因素对依从性的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To identify factors associated with adherence to radiology follow-up recommendations by the referring physicians.

MATERIALS AND METHODS: In this retrospective study, CT, ultrasound, and MRI reports with the keyword "recommend" and synonyms between March 11, 2019, and March 29, 2019, were included. Emergency department and inpatient examinations and routine surveillance recommendations, such as lung nodules, were excluded. Performance of follow-up examinations was correlated with the strength of recommendation, conditionality of recommendation, direct communication of results to ordering provider, and history of cancer. Outcomes included adherence to recommendations and time to follow-up. Statistical comparison between groups was performed using χ2, Kruskal-Wallis, and Spearman correlation.

RESULTS: Qualifying recommendations were provided in 255 reports (age 60.1 ± 16.5 years, female: 151 of 255, 59.22%). Imaging follow-up was performed in 166 of 255 (65%) reports: 148 of 166 (89.15%) nonconditional versus 18 of 166 (10.48%) conditional recommendations (P = .008), and more frequently in the patients with a strong follow-up recommendation (138 of 166 [83.13%], versus 28 of 166 [16.86%]) (P = .009). The median time to follow-up was 28 days versus 82 days in patients without versus with a history of cancer (P = .00057), 28 days versus 70 days with direct communication with the provider versus without (P = .0069), 82.5 versus 21 days for reports in which a specific follow-up interval was provided (86 of 255, 33.72%) versus those without (169 of 255, 66.27%) (P < .001).

CONCLUSION: The adherence rate for radiological nonroutine recommendations was 65%. Reports with strongly worded and nonconditional follow-up recommendations were followed more frequently. Direct communication with providers, patients without a known cancer history, and recommendations with no specified time interval identified were followed up earlier.

CLINICAL RELEVANCE: Strongly worded and nonconditional follow-up recommendations increase the likelihood of follow-up being performed. Direct communication of imaging follow-up recommendations to the provider and lack of specific time intervals decreases the median time to follow-up, which in turn may decrease the delay in medical care.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Kavandi, Wei, Al Bulushi, et al. Factors Affecting Adherence to Outpatient Radiology Report Recommendations. J Am Coll Radiol. 2023. PMID: 36990192. doi:10.1016/j.jacr.2023.03.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。