深度学习图像重建提升腹部双能CT病灶显示度
前瞻性纳入47例患者84个病灶,比较腹部双能CT门静脉期50keV虚拟单能图像中深度学习重建(DLIR)与50%自适应统计迭代重建(AV-50)的图像质量与病灶显示度。DLIR-H在噪声、SNR、CNR、图像质量主观评分及病灶显示度上均优于AV-50和DLIR-M,且不受病灶大小、相对CT衰减或临床目的影响。结论推荐DLIR-H用于日常低keV虚拟单能图像重建。
要点
- DLIR-H在50keV虚拟单能图像上病灶显示度优于AV-50和DLIR-M。
- DLIR-H和DLIR-M在图像对比度、噪声、锐利度、伪影感及诊断可接受性上均优于AV-50。
- DLIR较AV-50进一步降低噪声且更好保留噪声功率谱平均频率。
关键影像表现/征象
- DLIR较AV-50进一步降低图像噪声(p < 0.001),且更好保留噪声功率谱平均频率(p < 0.001)。
- DLIR保持CT值不变(p > 0.99),并较AV-50提高SNR和CNR(p < 0.001)。
- DLIR-H和DLIR-M在所有图像质量分析中评分均高于AV-50(p < 0.001)。
- DLIR-H的病灶显示度显著优于AV-50和DLIR-M,不受病灶大小、相对CT衰减或临床目的影响(p < 0.05)。
临床应用与阅片要点
- 日常腹部双能CT增强门静脉期低keV虚拟单能图像可优先采用DLIR-H重建以提升病灶显示度。
- DLIR-H在噪声降低的同时保留噪声功率谱平均频率,避免图像过度平滑。
- DLIR-H的病灶显示度优势不受病灶大小、相对CT衰减或临床目的影响,适用场景广泛。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate image quality, diagnostic acceptability, and lesion conspicuity in abdominal dual-energy CT (DECT) using deep learning image reconstruction (DLIR) compared to those using adaptive statistical iterative reconstruction-V (Asir-V) at 50% blending (AV-50), and to identify potential factors impacting lesion conspicuity.
METHODS: The portal-venous phase scans in abdominal DECT of 47 participants with 84 lesions were prospectively included. The raw data were reconstructed to virtual monoenergetic image (VMI) at 50 keV using filtered back-projection (FBP), AV-50, and DLIR at low (DLIR-L), medium (DLIR-M), and high strength (DLIR-H). A noise power spectrum (NPS) was generated. CT number and standard deviation values of eight anatomical sites were measured. Signal-to-noise (SNR), and contrast-to-noise ratio (CNR) values were calculated. Five radiologists assessed image quality in terms of image contrast, image noise, image sharpness, artificial sensation, and diagnostic acceptability, and evaluated the lesion conspicuity.
RESULTS: DLIR further reduced image noise (p < 0.001) compared to AV-50 while better preserved the average NPS frequency (p < 0.001). DLIR maintained CT number values (p > 0.99) and improved SNR and CNR values compared to AV-50 (p < 0.001). DLIR-H and DLIR-M showed higher ratings in all image quality analyses than AV-50 (p < 0.001). DLIR-H provided significantly better lesion conspicuity than AV-50 and DLIR-M regardless of lesion size, relative CT attenuation to surrounding tissue, or clinical purpose (p < 0.05).
CONCLUSIONS: DLIR-H could be safely recommended for routine low-keV VMI reconstruction in daily contrast-enhanced abdominal DECT to improve image quality, diagnostic acceptability, and lesion conspicuity.
KEY POINTS: • DLIR is superior to AV-50 in noise reduction, with less shifts of the average spatial frequency of NPS towards low frequency, and larger improvements of NPS noise, noise peak, SNR, and CNR values. • DLIR-M and DLIR-H generate better image quality in terms of image contrast, noise, sharpness, artificial sensation, and diagnostic acceptability than AV-50, while DLIR-H provides better lesion conspicuity than AV-50 and DLIR-M. • DLIR-H could be safely recommended as a new standard for routine low-keV VMI reconstruction in contrast-enhanced abdominal DECT to provide better lesion conspicuity and better image quality than the standard AV-50.
引用
- Zhong, Wang, Shen, et al. Improving lesion conspicuity in abdominal dual-energy CT with deep learning image reconstruction: a prospective study with five readers. Eur Radiol. 2023. PMID: 36976337. doi:10.1007/s00330-023-09556-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。