文献速递骨肌胸部技术与安全CT

基于深度学习的新鲜肋骨骨折自动检测与定位系统

An automatic fresh rib fracture detection and positioning system using deep learning.
PubMed 文献 · Br J Radiol · 2023-04-17

本研究回顾性收集8家医院18172例CT扫描,开发并评估了深度学习新鲜肋骨骨折检测与定位系统(FRF-DPS)。在多中心内部测试集(1612例)中,病灶水平敏感度0.933(95%CI 0.916-0.949),假阳性0.50(95%CI 0.397-0.583);外部测试集(2319例)中,FRF-DPS病灶水平敏感度0.909(95%CI 0.883-0.926)优于放射科医生0.789(95%CI 0.766-0.807),且肋骨定位准确率0.997(95%CI 0.992-1.000)优于医生0.981(95%CI 0.969-0.996),耗时减少20倍。

要点

  • FRF-DPS在外部测试集病灶水平敏感度0.909,优于放射科医生0.789。
  • FRF-DPS肋骨定位准确率0.997,高于医生0.981,且耗时减少20倍。
  • 在不同CT参数亚组中FRF-DPS表现稳健,敏感度0.894-0.927。

诊断标准与关键数值

  • 内部测试集病灶水平敏感度0.933(95%CI 0.916-0.949),假阳性0.50(95%CI 0.397-0.583)。
  • 外部测试集病灶水平FRF-DPS敏感度0.909(95%CI 0.883-0.926,p<0.001),假阳性0.379(95%CI 0.303-0.422,p=0.001)。
  • 外部测试集放射科医生病灶水平敏感度0.789(95%CI 0.766-0.807),假阳性0.496(95%CI 0.383-0.571)。
  • CT参数亚组分析中FRF-DPS敏感度0.894-0.927。
  • FRF-DPS肋骨定位准确率0.997(95%CI 0.992-1.000,p<0.001),医生为0.981(95%CI 0.969-0.996)。

局限性

  • 回顾性研究设计。
  • 外部测试集仅来自单一外部机构,泛化性需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the performance and robustness of a deep learning-based automatic fresh rib fracture detection and positioning system (FRF-DPS).

METHODS: CT scans of 18,172 participants admitted to eight hospitals from June 2009 to March 2019 were retrospectively collected. Patients were divided into development set (14,241), multicenter internal test set (1612), and external test set (2319). In internal test set, sensitivity, false positives (FPs) and specificity were used to assess fresh rib fracture detection performance at the lesion- and examination-levels. In external test set, the performance of detecting fresh rib fractures by radiologist and FRF-DPS were evaluated at lesion, rib, and examination levels. Additionally, the accuracy of FRF-DPS in rib positioning was investigated by the ground-truth labeling.

RESULTS: In multicenter internal test set, FRF-DPS showed excellent performance at the lesion- (sensitivity: 0.933 [95%CI, 0.916-0.949], FPs: 0.50 [95%CI, 0.397-0.583]) and examination-level. In external test set, the sensitivity and FPs at the lesion-level of FRF-DPS (0.909 [95%CI, 0.883-0.926], p < 0.001; 0.379 [95%CI, 0.303-0.422], p = 0.001) were better than the radiologist (0.789 [95%CI, 0.766-0.807]; 0.496 [95%CI, 0.383-0.571]), so were the rib- and patient-levels. In subgroup analysis of CT parameters, FRF-DPS were robust (0.894-0.927). Finally, FRF-DPS(0.997 [95%CI, 0.992-1.000], p < 0.001) is more accurate than radiologist (0.981 [95%CI, 0.969-0.996]) in rib positioning and takes 20 times less time.

CONCLUSION: FRF-DPS achieved high detection rate of fresh rib fractures with low FP values, and precise positioning of ribs, thus can be used in clinical practice to improve the detection rate and work efficiency.

ADVANCES IN KNOWLEDGE: We developed the FRF-DPS system which can detect fresh rib fractures and rib position, and evaluated by a large amount of multicenter data.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Li, Wu, Jiang, et al. An automatic fresh rib fracture detection and positioning system using deep learning. Br J Radiol. 2023. PMID: 36972072. doi:10.1259/bjr.20221006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。