前列腺T1 mapping:单次激发T1FLASH与MOLLI技术的伪影负荷及图像质量比较
一项前瞻性研究纳入100例疑似前列腺癌患者,在3T扫描仪上行多参数前列腺MRI,分别用MOLLI和新型单次激发T1FLASH反转恢复技术于钆对比剂注射前后行T1 mapping。结果示T1FLASH在注射对比剂后图像质量评分4.9±0.4,显著高于MOLLI的3.7±1.1(p<0.001),MOLLI注射后伪影发生率59%,主要源于尿液对比剂排泄及膀胱底对比剂积聚。结论认为T1FLASH是快速稳健的前列腺T1定量方法,适合注射对比剂后使用。
要点
- 注射钆对比剂后MOLLI伪影发生率高达59%,T1FLASH仅约7%,报告时需注意序列选择。
- MOLLI注射后图像质量评分3.7±1.1,显著低于T1FLASH的4.9±0.4(p<0.001)。
- 膀胱底对比剂积聚是MOLLI注射后严重伪影的主要来源,阅片时需识别并避免误判。
关键影像表现/征象
- T1FLASH图(注射前后)金属伪影出现率7%,磁敏感伪影1%。
- MOLLI图注射前金属伪影和磁敏感伪影各占6.5%。
- MOLLI图注射后伪影出现率59%,主要源于尿液对比剂排泄及膀胱底对比剂积聚,与T1FLASH注射后相比差异有统计学意义(p<0.01)。
- T1FLASH注射前图像质量评分4.9±0.4,MOLLI为4.8±0.6(p=0.14);注射后T1FLASH为4.9±0.4,MOLLI为3.7±1.1(p<0.001)。
临床应用与阅片要点
- 注射对比剂后行前列腺T1 mapping时优先选择T1FLASH序列,以避免膀胱底对比剂积聚造成的伪影。
- 阅片时注意MOLLI注射后图像中膀胱底及周围区域的高信号伪影,避免将其误认为病变或影响T1值测量。
- 金属伪影和磁敏感伪影在两种序列注射前均少见(约1%–7%),对图像质量影响有限。
局限性
- 单中心前瞻性研究,样本量100例,结果外推需谨慎。
- 原文未报告T1定量值与病理或临床结局的相关性,仅评估伪影和图像质量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess artifact burden and image quality of different MRI T1 mapping techniques of the prostate.
METHODS: Participants with suspected prostate cancer (PCa) were prospectively enrolled from June-October 2022 and examined with multiparametric prostate MRI (mpMRI; 3 T scanner; T1wi, T2wi, DWI und DCE). T1 mapping was performed before and after administration of gadolinium-based contrast-agent (GBCA) using (i) a modified Look-Locker inversion (MOLLI) technique and (ii) a novel single-shot T1FLASH inversion recovery technique. T2wi, DWI, T1FLASH and MOLLI sequences were systematically examined regarding prevalence of artifacts and image quality using a 5-point Likert-Scale.
RESULTS: A total of n = 100 patients were included (median age: 68 years). T1FLASH maps (pre-and post-GBCA) showed metal artifacts in 7% of cases and susceptibility artifacts in 1%. For MOLLI maps, pre-GBCA metal and susceptibility artifacts were documented in 6.5% of cases each. MOLLI maps post-GBCA showed artifacts in 59% of cases resulting primarily from urinary GBCA excretion and GBCA accumulation at the bladder base (p < 0.01 versus T1FLASH post-GBCA). Image quality for T1FLASH pre-GBCA was rated at a mean 4.9+/-0.4 and for MOLLI at 4.8+/-0.6 (p = 0.14). Post-GBCA image quality was rated at a mean 4.9+/-0.4 for T1FLASH and at 3.7+/-1.1 for MOLLI (p < 0.001).
CONCLUSIONS: T1FLASH maps provide a fast and robust method for quantification of T1 relaxation times of the prostate. T1FLASH is suitable for T1 mapping of the prostate following administration of contrast agents, while MOLLI T1 mapping is impaired through GBCA accumulation at the bladder base leading to severe image artifacts and reduced image quality.
引用
- Al-Bourini, Seif Amir Hosseini, Biggemann, et al. T1 mapping of the prostate using Single-Shot T1FLASH and MOLLI MRI Techniques: Comparison of artifact burden and image quality. Eur J Radiol. 2023. PMID: 36966698. doi:10.1016/j.ejrad.2023.110783
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。