多参数超声评估肝脏急性移植物抗宿主病:一项动物研究
该研究以48只雌性Wistar大鼠为受体、12只雄性Fischer 344大鼠为供体建立异基因造血干细胞移植后肝脏急性GVHD模型,每周随机选取8只行彩色多普勒超声、超声造影和剪切波色散成像,获取9项超声参数。结果显示MPUS各参数在aGVHD组与nGVHD组间均有统计学差异,基于主成分分析和支持向量机的分类模型准确率达100%,多参数分类器准确率显著高于单参数。
要点
- 彩色多普勒超声、超声造影和剪切波色散成像所得参数在肝脏aGVHD组与nGVHD组间均有统计学差异。
- 主成分分析中贡献最大的前三个参数依次为阻力指数、峰值强度和剪切波色散斜率。
- 支持向量机多参数分类器区分aGVHD与nGVHD的准确率达100%,显著高于单参数。
核心结论
- 多参数超声成像方法在检测肝脏急性移植物抗宿主病方面被证明是有用的。
研究设计与样本
- 研究为动物实验,48只雌性Wistar大鼠作为受体、12只雄性Fischer 344大鼠作为供体行异基因造血干细胞移植建立aGVHD模型。
- 移植后每周随机选取8只大鼠行超声检查,包括彩色多普勒超声、超声造影和剪切波色散成像,获取9项超声参数。
- 以组织病理学分析作为肝脏aGVHD的诊断参考标准。
诊断标准与关键数值
- MPUS获取的9项超声参数在aGVHD组与nGVHD组间均有统计学差异。
- 主成分分析结果中贡献百分比排名前三的参数依次为阻力指数、峰值强度和剪切波色散斜率。
- 支持向量机分类模型区分aGVHD与nGVHD的准确率达100%,多参数分类器准确率显著高于单参数。
临床应用与阅片要点
- 日常超声评估移植后肝脏aGVHD时可关注阻力指数、峰值强度和剪切波色散斜率等参数。
- 多参数联合分析较单一参数可能提高aGVHD与nGVHD的区分能力。
局限性
- 本研究为动物实验,结论外推至临床人群需谨慎。
- 原文未报告样本量估算、盲法及多中心验证等信息。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Hepatic acute graft-versus-host disease (aGVHD) is a serious complication of allogeneic hematopoietic stem cell transplantation (allo-HSCT) and is one of the leading causes of early non-recurrent death. The current diagnosis is based mainly based on clinical diagnosis, and there is a lack of non-invasive quantitative diagnosis methods. We propose a multiparametric ultrasound (MPUS) imaging method and explore its effectiveness in evaluating hepatic aGVHD.
METHODS: In this study, 48 female Wistar rats were used as receptors and 12 male Fischer 344 rats were used as donors for allo-HSCT to establish aGVHD models. After transplantation, 8 rats were randomly selected for ultrasonic examination weekly, including color Doppler ultrasound, contrast-enhanced ultrasound (CEUS) and shear wave dispersion (SWD) imaging. The values of nine ultrasonic parameters were obtained. Hepatic aGVHD was subsequently diagnosed by histopathological analysis. A classification model for predicting hepatic aGVHD was established using principal component analysis and support vector machines.
RESULTS: According to the pathological results, the transplanted rats were categorized into the hepatic aGVHD and non-GVHD (nGVHD) groups. All parameters obtained by MPUS differed statistically between the two groups. The first three contributing percentages of principal component analysis results were resistivity index, peak intensity and shear wave dispersion slope, respectively. The accuracy of classifying aGVHD and nGVHD using support vector machines reached 100%. The accuracy of the multiparameter classifier was significantly higher than that of the single parameter.
CONCLUSION: The MPUS imaging method has proven to be useful in detecting hepatic aGVHD.
引用
- Xiong, Xin, Qu, et al. Role of Multiparametric Ultrasound in Evaluating Hepatic Acute Graft-versus-Host Disease: An Animal Study. Ultrasound Med Biol. 2023. PMID: 36948895. doi:10.1016/j.ultrasmedbio.2023.02.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。