超低剂量CT联合人工智能迭代重建用于肺结节筛查:基于自动结节检测软件的评估
本研究通过体模和147例前瞻性筛查患者,测试超低剂量CT(0.18 mSv)联合人工智能迭代重建(AIIR)用于计算机辅助诊断(CAD)肺结节检测的可行性。体模主观图像质量AIIR优于FBP和HIR(p<0.001)。在常规剂量下结节数少于5个的107例挑战性病例中,ULD HIR和AIIR图像CAD结节检测性能分别为常规剂量的75.2%和92.2%。结论认为联合AIIR时,ULD CT方案(剂量降低95%)用于基于CAD的肺结节筛查是可行的。
要点
- 超低剂量CT(0.18 mSv)联合AIIR可实现95%剂量降低,用于CAD肺结节筛查可行。
- AIIR图像质量优于FBP和HIR(p<0.001),且CAD结节检测性能达常规剂量的92.2%。
- 在结节数少于5个的挑战性病例中,AIIR较HIR显著提升CAD检出率(92.2% vs 75.2%)。
关键影像表现/征象
- 体模主观图像质量评分AIIR高于FBP和HIR(p<0.001)。
- 常规剂量下107例患者结节数少于5个,被选为早期肺病的挑战性病例。
- 在该107例中,ULD HIR和AIIR图像CAD结节检测性能分别为常规剂量图像的75.2%和92.2%。
诊断标准与关键数值
- 体模图像质量采用五分制主观评分,比较用Mann-Whitney U检验。
- 结节检测性能以常规剂量图像为参考,评估ULD HIR和AIIR图像的CAD检测率。
临床应用与阅片要点
- 超低剂量CT联合AIIR可大幅降低辐射剂量至0.18 mSv,适合肺结节筛查场景。
- AIIR能提升CAD在超低剂量图像上的结节检出率,尤其对于结节数少的挑战性病例。
局限性
- 单中心前瞻性研究,样本量147例,外部推广需进一步验证。
- 体模与患者均来自同一机构,未报告多设备或多参数比较。
- 仅评估CAD检测性能,未报告诊断准确性的敏感度、特异度或AUC。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To test the feasibility of ultra-low-dose (ULD) computed tomography (CT) combined with an artificial intelligence iterative reconstruction (AIIR) algorithm for screening pulmonary nodules using computer-assisted diagnosis (CAD).
MATERIALS AND METHODS: A chest phantom with artificial pulmonary nodules was first scanned using the routine protocol and the ULD protocol (3.28 versus 0.18 mSv) to compare the image quality and to test the acceptability of the ULD CT protocol. Next, 147 lung-screening patients were enrolled prospectively, undergoing an additional ULD CT immediately after their routine CT examination for clinical validation. Images were reconstructed with filtered back-projection (FBP), hybrid iterative reconstruction (HIR), the AIIR, and were imported to the CAD software for preliminary nodule detection. Subjective image quality on the phantom was scored using a five-point scale and compared using the Mann-Whitney U-test. Nodule detection using CAD was evaluated for ULD HIR and AIIR images using the routine dose image as reference.
RESULTS: Higher image quality was scored for AIIR than for FBP and HIR at ULD (p<0.001). As reported by CAD, 107 patients were presented with fewer than five nodules on routine dose images and were chosen to represent the challenging cases at an early stage of pulmonary disease. Among such, the performance of nodule detection by CAD on ULD HIR and AIIR images was 75.2% and 92.2% of the routine dose image, respectively.
CONCLUSION: Combined with AIIR, it was feasible to use an ULD CT protocol with 95% dose reduction for CAD-based screening of pulmonary nodules.
引用
- Yang, Liu, Han, et al. Ultra-low-dose CT lung screening with artificial intelligence iterative reconstruction: evaluation via automatic nodule-detection software. Clin Radiol. 2023. PMID: 36948944. doi:10.1016/j.crad.2023.01.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。