主动脉及主动脉周围CT引导经皮空心针活检的安全性与准确性
本研究回顾性分析12年间单中心32例主动脉及主动脉周围CT引导经皮空心针活检,病灶平均最大径3.1 cm,针尖距血管内皮或心包深面平均1.0 cm。并发症发生率46.9%,其中93.3%为轻微;96.9%活检组织足以诊断,敏感度94.7%、特异度83.3%、准确率90.3%。结论认为该操作安全有效,诊断率高。
要点
- 主动脉及主动脉周围病灶CT引导活检诊断率高达96.9%,准确率90.3%。
- 并发症虽常见(46.9%),但绝大多数(93.3%)为轻微出血或疼痛。
- 针尖距血管内皮或心包深面平均1.0 cm,操作需注意邻近大血管风险。
核心结论
- CT引导经皮主动脉及主动脉周围空心针活检安全有效,诊断率高。
研究设计与样本
- 单中心回顾性研究,纳入2010年2月至2022年8月共30例患者32次活检。
- 活检区域与主动脉或大血管(包括心包和髂总动脉)直接接触。
- 并发症采用常见不良事件评价标准5.0版分级,病理与后续活检或手术病理及临床过程对照判断一致性。
诊断标准与关键数值
- 病灶平均最长径3.1 cm(范围0.5-10.9 cm),针尖距血管内皮或心包深面平均1.0 cm(范围0.3-1.8 cm)。
- 并发症发生率46.9%(15/32),其中93.3%(14/15)为轻微,包括少量出血或疼痛;1例发生少量非急诊气胸。
- 96.9%(31/32)活检组织足以诊断;敏感度94.7%,特异度83.3%,阳性预测值90.0%,阴性预测值90.9%,准确率(诊断率)90.3%。
临床应用与阅片要点
- 对于主动脉及主动脉周围病灶,CT引导空心针活检可作为获取病理的诊断手段。
- 操作中需关注针尖与血管内皮或心包的距离,本组平均1.0 cm,需警惕出血和气胸等并发症。
- 尽管并发症发生率较高,但多为轻微,临床可接受。
局限性
- 单中心回顾性设计,样本量较小(30例患者32次活检)。
- 并发症评估依赖临床记录,可能存在遗漏。
- 部分病例缺乏后续手术病理对照,一致性判断可能受限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The purpose of this study was to determine the safety and accuracy of aortic and periaortic computed tomography (CT)-guided percutaneous core needle biopsy performed at a single center over 12 years.
MATERIALS AND METHODS: A retrospective review was conducted of cases performed between February 2010 and August 2022 in which the biopsied region was in direct contact with the aorta or great vessels including the pericardium and common iliac arteries. Clinical notes were reviewed for any early or delayed complications following the procedure, which if present were graded using the National Institute of Health's Common Terminology Criteria for Adverse Events, version 5.0. Pathology results were compared to subsequent outside biopsy results or follow-up surgical pathology, if available, as well as subsequent clinical decision making and/or clinical course, to determine concordance. Sensitivity, specificity, predictive value, and accuracy (indicative of diagnostic yield) were calculated.
RESULTS: 32 core needle biopsies were reviewed from 30 patients (average lesion longest diameter 3.1 cm, range 0.5-10.9 cm; average needle proximity to the vessel endothelium or deep side of the pericardium 1.0 cm, range 0.3-1.8 cm). Complications occurred in 46.9% of cases (15/32), 93.3% (14/15) of which were minor and included small amounts of bleeding or pain. One patient developed a small nonemergent pneumothorax. Of biopsies obtained, 96.9% provided adequate tissue for diagnosis (31/32). When evaluating concordance between pathological and final diagnosis, sensitivity was 94.7% and specificity was 83.3%; positive and negative predictive value were 90.0% and 90.9%, respectively. Accuracy (diagnostic yield) of biopsy was 90.3%.
CONCLUSION: CT-guided percutaneous aortic and periaortic core needle biopsies are safe and efficacious procedures with high diagnostic yield.
引用
- Pitot, Gu, Adamo, et al. Safety and accuracy of aortic and periaortic CT-guided percutaneous core needle biopsy. Abdom Radiol (NY). 2023. PMID: 36939909. doi:10.1007/s00261-023-03867-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。