文献速递外周血管介入DSA

基于设备剂量学信息优化放射预警阈值以预测血管介入中2-4 Gy峰值皮肤剂量

Optimized radiological alert thresholds based on device-dosimetric information to predict peak skin dose between 2 and 4 Gy during vascular fluoroscopically guided intervention.
PubMed 文献 · Eur Radiol · 2023-03-17

本研究基于258例血管介入患者的峰值皮肤剂量计算,利用3D-ROC曲线分析kerma和KAP的优化阈值,发现优化阈值在预测2000-4000 mGy峰值皮肤剂量时敏感度和特异度均优于NCRP阈值,最佳优化阈值为kerma 3020.5 mGy和KAP 741.02 Gy.cm2(对应PSD 3300 mGy),可改善患者随访。

要点

  • 对于血管介入,kerma>3020.5 mGy或KAP>741.02 Gy.cm2提示峰值皮肤剂量可能超过3300 mGy。
  • 优化阈值预测高皮肤剂量的敏感度和特异度均优于NCRP经典阈值。
  • 建议各机构可借鉴此方法制定本机构的实质性辐射剂量水平(SRDL)。

局限性

  • 单中心研究,结果外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To provide radiologists and physicists with methodological tools to improve patient management after vascular fluoroscopically guided intervention (FGI) by providing optimized thresholds (OT) values that could be used as a surrogate to the thresholds classically proposed by the National Council on Radiation Protection (NCRP) or could be useful to adapt their own substantial radiation dose levels (SRDL) values.

METHODS: PSD of 2000-4000 mGy after FGI were calculated for 258 patients with dedicated software. Overall, the kerma and KAP 3D-ROC curves were used to assess the sensitivity (SEN) and specificity (SPE) of NCRP thresholds and OT for each PSD. Kiviat diagram and density curves were plotted for the best SEN/SPE pair of 3D-ROC curves and compared to the NCRP thresholds.

RESULTS: OT for both kerma and KAP generating the best SEN/SPE couple for PSD of 2000-4000 mGy were obtained. The SEN/SPE couple of each OT was always better than that obtained using NCRP ones. The best OT among all those calculated providing the highest SEN/SPE values for kerma (3020.5 mGy) and KAP (741.02 Gy.cm2) were obtained when PSD was equal to 3300 mGy.

CONCLUSIONS: We have calculated OT in terms of kerma and KAP based on 3D-ROC curves analysis and peak skin dose calculations that can be obtained to better predict high skin dose. The use of OT that predicted PSD greater than 3000 mGy is likely to improve patient follow-up. The methodology developed in this work could be adapted to other institutions in order to better define their own SRDL.

KEY POINTS: • Optimized dose thresholds in terms of kerma and KAP based on 3D-ROC curves analysis and peak skin dose calculations between 2000 and 4000 mGy can be obtained to better predict high skin dose. • Patients receiving a peak skin dose between 2000 and 4000 mGy have their follow-up enhanced by using the optimized thresholds instead of the NCRP thresholds. • The best-optimized thresholds, corresponding to 3020.5 mGy and 741.02 Gy.cm2 for kerma and KAP respectively can be used instead of NRCP ones to trigger patient follow-up after fluoroscopically guided vascular interventions.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Sas, Lacroix, Dedieu, et al. Optimized radiological alert thresholds based on device-dosimetric information to predict peak skin dose between 2 and 4 Gy during vascular fluoroscopically guided intervention. Eur Radiol. 2023. PMID: 36932215. doi:10.1007/s00330-023-09538-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。