文献速递胸部MR

径向K空间填充百分比与信号平均对三维径向UTE肺MRI图像质量的影响:预试验

Impact of Radial Percentage K-Space Filling and Signal Averaging on Native Lung MRI Image Quality in 3D Radial UTE Acquisition: A Pilot Study.
PubMed 文献 · Acad Radiol · 2023-03-16

一项前瞻性预试验纳入25例10–30岁非肺部适应症患者,比较三种三维径向UTE序列参数(R100/200、NSA1/2)的肺MRI图像质量。主观评估显示R100_NSA2序列在胸膜及纵隔面轮廓、肺实质、段支气管显示最佳,整体图像质量最好且伪影最少;客观SNR、CNR及对比度在三序列间无统计学显著差异。

要点

  • R100_NSA2序列对胸膜/纵隔面、肺实质及段支气管显示最佳,整体图像质量最好。
  • 主支气管在R100_NSA2与R100_NSA1序列均显示良好。
  • 客观SNR、CNR及对比度在三序列间无统计学显著差异。

核心结论

  • R100_NSA2 UTE序列在各项影像表现评估中表现最佳,且图像质量最好、伪影最少。

研究设计与样本

  • 所有患者均行肺MRI,采用三种不同UTE序列参数:径向百分比R为100或200,信号平均次数NSA为1或2。
  • 由两名放射科医生独立评估胸膜及纵隔面轮廓、肺实质、主支气管及段支气管的可见性,并根据运动伪影程度评估图像质量。
  • 客观评估计算信噪比、对比噪声比及对比度。

关键影像表现/征象

  • 胸膜及纵隔面轮廓、肺实质及段支气管在R100_NSA2序列上显示最佳。
  • 主支气管在R100_NSA2及R100_NSA1序列上显示最佳。
  • 序列间差异仅在胸膜及纵隔面轮廓和段支气管评估中具有统计学显著性(p < 0.05)。
  • 整体图像质量最好且伪影最少见于R100_NSA2序列。
  • R100_NSA2与R200_NSA1序列的观察者间一致性为中等至几乎完全一致。

诊断标准与关键数值

  • 主观图像质量评估指标包括胸膜及纵隔面轮廓、肺实质、主支气管、段支气管可见性及运动伪影程度。
  • 客观评估指标为信噪比、对比噪声比及对比度,三序列间差异无统计学显著性(p > 0.05)。

临床应用与阅片要点

  • 在三维径向UTE肺MRI中,优先选择R100_NSA2参数以优化胸膜/纵隔面、肺实质及段支气管的显示。
  • 若需兼顾主支气管显示与扫描效率,R100_NSA1也可作为备选。
  • 客观SNR/CNR在三序列间无显著差异,提示主观图像质量评估对序列选择具有重要参考价值。

局限性

  • 本研究为预试验,样本量较小(25例),结论需更大样本验证。
  • 研究对象为10–30岁非肺部适应症患者,可能无法完全代表肺部疾病患者。
  • 仅比较了三种序列参数组合,未涵盖其他可能的参数设置。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVE: To assess the impact of radial percentage k-space filling and signal averaging on lung MRI image quality in 3D radial ultrashort echo-time (UTE) acquisition.

MATERIALS AND METHODS: In this IRB approved prospective study, 25 patients (10-30 years) referred for MRI examination for indications other than related to lungs were enrolled from January 2021 to November 2021. All the patients underwent lung MRI, using three different UTE sequence parameters with radial (R) percentage of 100 or 200 and number of signal averages (NSA) of one or two. Two radiologists independently assessed the images for the outline of pleural and mediastinal surface, visibility of lung parenchyma, major bronchi, and segmental bronchi. The quality of the images was assessed based on the degree of motion artifacts. For objective assessment, signal-to-noise ratio, contrast-to-noise ratio, and contrast ratio were calculated.

RESULTS: The outline of pleural and mediastinal surface, lung parenchyma, and segmental bronchi were best demonstrated on R100_NSA2 sequence. The major bronchi were best demonstrated on R100_NSA2 and R100_NSA1 sequences. The intersequence difference was statistically significant for evaluating the pleural and mediastinal surface and segmental bronchi only (p < 0.05). Overall, the best image quality with least artifacts was seen with R100_NSA2 sequence. The objective assessment showed no statistically significant difference between the three sequences (p > 0.05). Interobserver agreement for different findings was substantial to almost perfect for R100_NSA2 and R200_NSA1 sequences.

CONCLUSION: R100_NSA2 UTE sequence performed best for the evaluation of the different findings and showed the best image quality.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Sodhi, Bhatia, Rana, et al. Impact of Radial Percentage K-Space Filling and Signal Averaging on Native Lung MRI Image Quality in 3D Radial UTE Acquisition: A Pilot Study. Acad Radiol. 2023. PMID: 36931950. doi:10.1016/j.acra.2023.01.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。