非穿孔性十二指肠球部溃疡的CT诊断算法开发与验证
该回顾性研究纳入135例非穿孔性十二指肠球部溃疡患者和150例球部正常对照,比较临床与CT特征,构建二元logistic回归模型,并在另一中心80例患者中外部验证。模型纳入消化道出血、球壁厚度≥4.85 mm、黏膜面不规则及周围脂肪间隙模糊,训练集AUC为0.974,外部验证AUC为0.916。
要点
- 球壁厚度≥4.85 mm是非穿孔性十二指肠球部溃疡的独立预测因素。
- 黏膜面不规则和球周脂肪间隙模糊是重要CT征象,需在多平面重建中仔细评估。
- 结合消化道出血临床信息可提高CT诊断非穿孔性十二指肠球部溃疡的效能。
关键影像表现/征象
- 溃疡组十二指肠球壁厚度显著大于对照组(p<0.001)。
- 黏膜面不规则、分层强化及球周脂肪间隙模糊在溃疡组更常见(均p<0.001)。
- 消化道出血在非穿孔性十二指肠球部溃疡患者中更频繁(p<0.001)。
诊断标准与关键数值
- 二元logistic回归显示消化道出血、球壁厚度≥4.85 mm、黏膜面不规则及周围脂肪间隙模糊是与非穿孔性十二指肠球部溃疡最显著的相关因素。
- 模型训练集AUC为0.974,外部验证集AUC为0.916。
临床应用与阅片要点
- 阅片时应关注十二指肠球壁厚度,≥4.85 mm需警惕非穿孔性十二指肠球部溃疡。
- 结合黏膜面不规则、分层强化及球周脂肪间隙模糊等征象,并询问消化道出血病史。
- 多平面重建有助于准确评估球壁厚度和周围脂肪间隙。
局限性
- 研究为回顾性设计。
- 训练集和验证集样本量有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the value of multiplanar computed tomography (CT) in the diagnosis of nonperforated duodenal bulb ulcer (NPDBU).
METHOD: We retrospectively analyzed data from 135 patients with NPDBU (ulcer group) and 150 patients with a normal duodenal bulb (control group) who underwent contrast-enhanced abdominal CT and were diagnosed via upper endoscopy from January 2018 to February 2022. The clinical and CT features were compared between the two groups. Independent prognostic factors for diagnosing NPDBU were determined using binary logistic regression analysis. An external validation cohort to determine the model's efficiency comprised 80 patients from another center.
RESULTS: Gastrointestinal bleeding was more frequent in patients with NPDBU than in those without (p < 0.001). No significant differences in age and sex were observed between the groups (all p > 0.05). The duodenal bulbar wall was significantly thicker in the ulcer group than in the control group, as determined using CT (p < 0.001). Irregular mucosal surface, layered enhancement, and blurred fat space around the duodenal bulb were more common in the ulcer group than in the control group (all p < 0.001). Binary logistic regression analysis revealed that gastrointestinal bleeding, wall thickness of ≥ 4.85 mm, irregular mucosal surface, and blurred peripheral fat space were the most significant variations associated with NPDBU, with an area under the curve (AUC) of 0.974. The external validation cohort had an AUC of 0.916.
CONCLUSIONS: Careful multiplanar CT interpretation suggests the underlying presence of NPDBU and allows timely endoscopic verification and appropriate treatment.
引用
- Gong, Zhang, Luo, et al. Development and validation of a CT algorithm for the identification of nonperforated duodenal bulb ulcer. Eur J Radiol. 2023. PMID: 36917926. doi:10.1016/j.ejrad.2023.110761
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。