基于DTI指标与影像特征预测子宫肌瘤HIFU消融疗效
消融充分组FA、RA值更高,VR、MD值更低;RA与强化程度联合模型AUC达0.915,预测效能优于单独FA或MD。
要点
- 术前DTI的RA值与肌瘤强化程度联合模型可预测HIFU消融是否充分,AUC为0.915。
- 消融充分组FA、RA值更高,VR、MD值更低,差异均有统计学意义(p<0.05)。
- 联合模型预测效能优于单独FA(p=0.032)和MD(p<0.001),但与RA、VR单指标相比无显著提升(p>0.05)。
核心结论
- DTI指标尤其是联合影像特征的模型,可作为预测子宫肌瘤HIFU消融疗效的影像工具。
关键影像表现/征象
- 消融充分组(NPVR≥70%,42个肌瘤)FA和RA值高于消融不充分组(NPVR<70%,43个肌瘤),VR和MD值低于消融不充分组(p<0.05)。
诊断标准与关键数值
- 以NPVR≥70%定义为消融充分,NPVR<70%为消融不充分。
- RA与强化程度联合模型预测消融充分的AUC为0.915。
- 联合模型预测效能优于单独FA(p=0.032)和单独MD(p<0.001),与RA、VR相比无显著差异(p>0.05)。
临床应用与阅片要点
- 术前可参考DTI指标RA值及肌瘤强化程度评估HIFU消融能否达到NPVR≥70%,辅助筛选患者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To predict the efficacy of high-intensity focused ultrasound (HIFU) ablation for uterine leiomyomas based on diffusion tensor imaging (DTI) indicators and imaging features.
METHODS: Sixty-two patients with 85 uterine leiomyomas were consecutively enrolled in this retrospective study and underwent DTI scanning before HIFU treatment. Based on whether the non-perfused volume ratio (NPVR) was greater than 70%, all patients were assigned to sufficient ablation (NPVR ≥ 70%) or insufficient ablation (NPVR < 70%) groups. The selected DTI indicators and imaging features were incorporated to construct a combined model. The predictive performance of DTI indicators and the combined model were assessed using receiver operating characteristic (ROC) curves.
RESULTS: There were 42 leiomyomas in the sufficient ablation group (NPVR ≥ 70%) and 43 leiomyomas in the insufficient ablation group (NPVR < 70%). The fractional anisotropy (FA) and relative anisotropy (RA) values were higher in the sufficient ablation group than in the insufficient ablation group (p < 0.05). Conversely, the volume ratio (VR) and mean diffusivity (MD) values were lower in the sufficient ablation group than those in the insufficient ablation group (p < 0.05). Notably, the combined model composed of the RA and enhancement degree values had high predictive efficiency, with an AUC of 0.915. The combined model demonstrated higher predictive performance than FA and MD alone (p = 0.032 and p < 0.001, respectively) but showed no significant improvement compared with RA and VR (p > 0.05).
CONCLUSION: DTI indicators, especially the combined model incorporating DTI indicators and imaging features, can be a promising imaging tool to assist clinicians in predicting HIFU efficacy for uterine leiomyomas.
引用
- Qin, Jiang, Wang, et al. Predicting the efficacy of high-intensity focused ultrasound (HIFU) ablation for uterine leiomyomas based on DTI indicators and imaging features. Abdom Radiol (NY). 2023. PMID: 36912910. doi:10.1007/s00261-023-03865-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。