文献速递泌尿生殖腹部MR

反向编码畸变校正用于前列腺DWI:提升图像质量与ADC鉴别良恶性效能

Reverse encoding distortion correction for diffusion-weighted MRI: Efficacy for improving image quality and ADC evaluation for differentiating malignant from benign areas in suspected prostatic cancer patients.
PubMed 文献 · Eur J Radiol · 2023-03-05

RDC DWI的SNR和整体图像质量显著提高,ADC的AUC、特异度和准确率均显著优于常规DWI,提示RDC可改善前列腺DWI图像质量及良恶性鉴别能力。

要点

  • RDC DWI可显著提高良性区及肌肉的SNR和整体图像质量。
  • RDC DWI的ADC鉴别良恶性效能优于常规DWI(AUC 0.85 vs 0.79)。
  • RDC主要提升特异度和准确率,敏感度未见显著差异。

局限性

  • 单中心研究。
  • 良性区域为计算机选取,非全部经病理证实。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The purpose of this study was to determine the influenceof reverse encoding distortion correction (RDC) on ADC measurement and its efficacy for improving image quality and diagnostic performance for differentiating malignant from benign prostatic areas on prostatic DWI.

METHODS: Forty suspected prostatic cancer patients underwent DWI with or without RDC (i.e. RDC DWI or DWI) using a 3 T MR system as well as pathological examinations. The pathological examination results indicated 86 areas were malignant while 86 out of 394 areas were computationally selected as benign. SNR for benign areas and muscle and ADCs for malignant and benign areas were determined by ROI measurements on each DWI. Moreover, overall image quality was assessed with a 5-point visual scoring system on each DWI. Paired t-test or Wilcoxon's signed rank test was performed to compare SNR and overall image quality for DWIs. ROC analysis was then used to compare the diagnostic performance, and sensitivity (SE), specificity (SP) and accuracy (AC) of ADC were compared between two DWI by means of McNemar's test.

RESULTS: SNR and overall image quality of RDC DWI showed significant improvements when compared with those of DWI (p < 0.05). Areas under the curve (AUC), SP and AC of DWI RDC DWI (AUC: 0.85, SP: 72.1%, AC: 79.1%) were significantly better than those of DWI (AUC: 0.79, p = 0.008; SP: 64%, p = 0.02; AC: 74.4%, p = 0.008).

CONCLUSION: RDC technique has the potential to improve image quality and ability to differentiate malignant from benign prostatic areas on DWIs of suspected prostatic cancer patients.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Ueda, Ohno, Shinohara, et al. Reverse encoding distortion correction for diffusion-weighted MRI: Efficacy for improving image quality and ADC evaluation for differentiating malignant from benign areas in suspected prostatic cancer patients. Eur J Radiol. 2023. PMID: 36905716. doi:10.1016/j.ejrad.2023.110764

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。