前列腺MRI靶向活检中索引病灶勾画的放射科与泌尿科医师间差异评估
结果显示两组间Dice相似系数(0.41 vs. 0.59)和95% Hausdorff距离(6.38 mm vs. 4.47 mm)均显著低于放射科医师之间,且一致性随病灶增大而提高。提示勾画差异可能导致靶向活检假阴性,支持病灶周围活检的必要性。
要点
- 泌尿科医师与放射科医师对前列腺索引病灶的勾画一致性显著低于放射科医师之间,DSC仅0.41。
- 病灶≤10 mm时勾画一致性更差,小病灶靶向活检的假阴性风险更高。
- PI-RADS评分、带区位置、病灶清晰度和PSHS对勾画一致性无显著影响。
关键影像表现/征象
- 前列腺索引病灶在T2w图像上的勾画范围在泌尿科医师与放射科医师之间存在肉眼可见的差异。
- 病灶≤10 mm时勾画一致性更差,而病灶较大时一致性提高。
- 病灶带区位置、PI-RADS评分、病灶清晰度及PSHS评分对勾画一致性无显著影响。
诊断标准与关键数值
- 勾画一致性采用Dice相似系数(DSC)和95% Hausdorff距离(95% HD)评估。
- 泌尿科医师与放射科医师间的平均DSC为0.41 ± 0.24,放射科医师间为0.59 ± 0.23(p < 0.01)。
- 泌尿科医师与放射科医师间的平均95% HD为6.38 ± 5.45 mm,放射科医师间为4.47 ± 4.12 mm(p < 0.01)。
- DSC与病灶大小的相关性:泌尿科医师与放射科医师间ρ = 0.331(p = 0.002),放射科医师间ρ = 0.501(p < 0.001)。
临床应用与阅片要点
- 阅片时对前列腺小病灶(≤10 mm)的勾画需格外谨慎,因不同医师间勾画差异较大,可能增加靶向活检假阴性风险。
- 报告索引病灶时应明确描述病灶大小和边界,以促进泌尿科与放射科医师之间的沟通和勾画一致性。
- 考虑在靶向活检中结合病灶周围活检,以弥补勾画不准确可能导致的漏诊。
局限性
- 回顾性单中心研究设计。
- 仅基于T2w图像评估勾画一致性,未涉及其他序列。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Mistargeting of focal lesions due to inaccurate segmentations can lead to false-negative findings on MRI-guided targeted biopsies. The purpose of this retrospective study was to examine inter-reader agreement of prostate index lesion segmentations from actual biopsy data between urologists and radiologists.
METHOD: Consecutive patients undergoing transperineal MRI-targeted prostate biopsy for PI-RADS 3-5 lesions between January 2020 and December 2021 were included. Agreement between segmentations on T2w-images between urologists and radiologists was assessed with Dice similarity coefficient (DSC) and 95 % Hausdorff distance (95 % HD). Differences in similarity scores were compared using Wilcoxon test. Differences depending on lesion features (size, zonal location, PI-RADS scores, lesion distinctness) were tested with Mann-Whitney U test. Correlation with prostate signal-intensity homogeneity score (PSHS) and lesion size was tested with Spearman's rank correlation.
RESULTS: Ninety-three patients (mean age 64.9 ± 7.1y, median serum PSA 6.5 [4.33-10.00]) were included. Mean similarity scores were statistically significantly lower between urologists and radiologists compared to radiologists only (DSC 0.41 ± 0.24 vs. 0.59 ± 0.23, p < 0.01; 95 %HD 6.38 ± 5.45 mm vs. 4.47 ± 4.12 mm, p < 0.01). There was a moderate and strong positive correlation between DSC scores and lesion size for segmentations from urologists and radiologists (ρ = 0.331, p = 0.002) and radiologists only (ρ = 0.501, p < 0.001). Similarity scores were worse in lesions ≤ 10 mm while other lesion features did not significantly influence similarity scores.
CONCLUSION: There is significant mismatch of prostate index lesion segmentations between urologists and radiologists. Segmentation agreement positively correlates with lesion size. PI-RADS scores, zonal location, lesion distinctness, and PSHS show no significant impact on segmentation agreement. These findings could underpin benefits of perilesional biopsies.
引用
- Ghafoor, Steinebrunner, Stocker, et al. Index lesion contouring on prostate MRI for targeted MRI/US fusion biopsy - Evaluation of mismatch between radiologists and urologists. Eur J Radiol. 2023. PMID: 36898172. doi:10.1016/j.ejrad.2023.110763
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。