基于深度学习的自动化新生儿脑部神经影像处理流程
本研究开发并验证了一个基于深度学习的端到端流程,用于新生儿脑结构MRI的分割与分析。在两个队列(582名来自dHCP的新生儿和37名本院3.0T MRI扫描新生儿)中,该流程可将脑分割为9种组织和87个结构,并在薄层和厚层图像上均表现出高精度和可重复性。
要点
- 该流程可自动分割新生儿脑为9种组织和87个结构,薄层图像上最佳DSC为0.96,H95为0.99 mm。
- 区域体积和皮质表面分析方面与金标准一致性良好,区域体积ICC均高于0.80。
- 厚层图像上分割性能略有下降(最佳DSC 0.92,H95 3.00 mm),区域体积和表面曲率ICC略低于0.80。
诊断标准与关键数值
- 薄层图像上,脑组织和结构分割的最佳DSC为0.96,H95为0.99 mm。
- 区域体积分析的ICC值均高于0.80。
- 厚层图像上,脑分割的最佳DSC为0.92,H95为3.00 mm。
- 厚层图像上,区域体积和表面曲率的ICC值略低于0.80。
临床应用与阅片要点
- 该流程可用于新生儿脑结构MRI的自动分割和定量分析,辅助评估脑组织发育和早期神经发育异常。
- 在厚层图像上应用时需注意分割精度和体积/表面测量的一致性略有降低。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Accurate segmentation of neonatal brain tissues and structures is crucial for studying normal development and diagnosing early neurodevelopmental disorders. However, there is a lack of an end-to-end pipeline for automated segmentation and imaging analysis of the normal and abnormal neonatal brain.
OBJECTIVE: To develop and validate a deep learning-based pipeline for neonatal brain segmentation and analysis of structural magnetic resonance images (MRI).
MATERIALS AND METHODS: Two cohorts were enrolled in the study, including cohort 1 (582 neonates from the developing Human Connectome Project) and cohort 2 (37 neonates imaged using a 3.0-tesla MRI scanner in our hospital).We developed a deep leaning-based architecture capable of brain segmentation into 9 tissues and 87 structures. Then, extensive validations were performed for accuracy, effectiveness, robustness and generality of the pipeline. Furthermore, regional volume and cortical surface estimation were measured through in-house bash script implemented in FSL (Oxford Centre for Functional MRI of the Brain Software Library) to ensure reliability of the pipeline. Dice similarity score (DSC), the 95th percentile Hausdorff distance (H95) and intraclass correlation coefficient (ICC) were calculated to assess the quality of our pipeline. Finally, we finetuned and validated our pipeline on 2-dimensional thick-slice MRI in cohorts 1 and 2.
RESULTS: The deep learning-based model showed excellent performance for neonatal brain tissue and structural segmentation, with the best DSC and the 95th percentile Hausdorff distance (H95) of 0.96 and 0.99 mm, respectively. In terms of regional volume and cortical surface analysis, our model showed good agreement with ground truth. The ICC values for the regional volume were all above 0.80. Considering the thick-slice image pipeline, the same trend was observed for brain segmentation and analysis. The best DSC and H95 were 0.92 and 3.00 mm, respectively. The regional volumes and surface curvature had ICC values just below 0.80.
CONCLUSIONS: We propose an automatic, accurate, stable and reliable pipeline for neonatal brain segmentation and analysis from thin and thick structural MRI. The external validation showed very good reproducibility of the pipeline.
引用
- Shen, Bao, Wang, et al. An automatic and accurate deep learning-based neuroimaging pipeline for the neonatal brain. Pediatr Radiol. 2023. PMID: 36884052. doi:10.1007/s00247-023-05620-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。