文献速递心血管US

机器学习优化主动脉瓣狭窄的超声随访

Machine Learning to Optimize the Echocardiographic Follow-Up of Aortic Stenosis.
PubMed 文献 · JACC Cardiovasc Imaging · 2023-02-08

本研究开发并验证机器学习模型,预测轻中度主动脉瓣狭窄患者1、2、3年内进展为重度瓣膜病的风险,内部验证AUC-ROC分别为0.90、0.92、0.92,外部验证均为0.85。模拟应用显示,与欧美指南相比,该模型每年可分别减少49%和13%的不必要超声检查。

要点

  • 模型可实时个体化预测轻中度主动脉瓣狭窄患者1-3年内进展为重度的风险。
  • 外部验证AUC-ROC均为0.85, discriminative ability良好。
  • 与欧美指南相比,模型可减少不必要超声随访检查。
英文原文(摘要)· 点击展开

BACKGROUND: Disease progression in patients with mild-to-moderate aortic stenosis is heterogenous and requires periodic echocardiographic examinations to evaluate severity.

OBJECTIVES: This study sought to explore the use of machine learning to optimize aortic stenosis echocardiographic surveillance automatically.

METHODS: The study investigators trained, validated, and externally applied a machine learning model to predict whether a patient with mild-to-moderate aortic stenosis will develop severe valvular disease at 1, 2, or 3 years. Demographic and echocardiographic patient data to develop the model were obtained from a tertiary hospital consisting of 4,633 echocardiograms from 1,638 consecutive patients. The external cohort was obtained from an independent tertiary hospital, consisting of 4,531 echocardiograms from 1,533 patients. Echocardiographic surveillance timing results were compared with the European and American guidelines echocardiographic follow-up recommendations.

RESULTS: In internal validation, the model discriminated severe from nonsevere aortic stenosis development with an area under the receiver-operating characteristic curve (AUC-ROC) of 0.90, 0.92, and 0.92 for the 1-, 2-, or 3-year interval, respectively. In external application, the model showed an AUC-ROC of 0.85, 0.85, and 0.85, for the 1-, 2-, or 3-year interval. A simulated application of the model in the external validation cohort resulted in savings of 49% and 13% of unnecessary echocardiographic examinations per year compared with European and American guideline recommendations, respectively.

CONCLUSIONS: Machine learning provides real-time, automated, personalized timing of next echocardiographic follow-up examination for patients with mild-to-moderate aortic stenosis. Compared with European and American guidelines, the model reduces the number of patient examinations.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Sánchez-Puente, Dorado-Díaz, Sampedro-Gómez, et al. Machine Learning to Optimize the Echocardiographic Follow-Up of Aortic Stenosis. JACC Cardiovasc Imaging. 2023. PMID: 36881417. doi:10.1016/j.jcmg.2022.12.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。