本研究在丹麦四家医院回顾性纳入1529例成人后前位胸片,用三种胸部放射科医师标注的参考标准评估商用AI工具。AI对异常胸片的敏感度为99.1%,对危急异常为99.8%,均高于临床放射科报告;AI自主报告了28.0%的正常胸片,占全部胸片的7.8%。

要点

  • AI对异常胸片敏感度99.1%,对危急异常99.8%,高于放射科报告。
  • AI可自主报告28.0%的正常胸片,占全部胸片的7.8%。
  • AI高敏感度有助于减少漏诊,但自主报告率有限。

局限性

  • 回顾性研究设计。
  • 参考标准基于胸片表现而非临床最终诊断。
  • 临床放射科报告因文本不足排除22份。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Automated interpretation of normal chest radiographs could alleviate the workload of radiologists. However, the performance of such an artificial intelligence (AI) tool compared with clinical radiology reports has not been established. Purpose To perform an external evaluation of a commercially available AI tool for (a) the number of chest radiographs autonomously reported, (b) the sensitivity for AI detection of abnormal chest radiographs, and (c) the performance of AI compared with that of the clinical radiology reports. Materials and Methods In this retrospective study, consecutive posteroanterior chest radiographs from adult patients in four hospitals in the capital region of Denmark were obtained in January 2020, including images from emergency department patients, in-hospital patients, and outpatients. Three thoracic radiologists labeled chest radiographs in a reference standard based on chest radiograph findings into the following categories: critical, other remarkable, unremarkable, or normal (no abnormalities). AI classified chest radiographs as high confidence normal (normal) or not high confidence normal (abnormal). Results A total of 1529 patients were included for analysis (median age, 69 years [IQR, 55-69 years]; 776 women), with 1100 (72%) classified by the reference standard as having abnormal radiographs, 617 (40%) as having critical abnormal radiographs, and 429 (28%) as having normal radiographs. For comparison, clinical radiology reports were classified based on the text and insufficient reports excluded (n = 22). The sensitivity of AI was 99.1% (95% CI: 98.3, 99.6; 1090 of 1100 patients) for abnormal radiographs and 99.8% (95% CI: 99.1, 99.9; 616 of 617 patients) for critical radiographs. Corresponding sensitivities for radiologist reports were 72.3% (95% CI: 69.5, 74.9; 779 of 1078 patients) and 93.5% (95% CI: 91.2, 95.3; 558 of 597 patients), respectively. Specificity of AI, and hence the potential autonomous reporting rate, was 28.0% of all normal posteroanterior chest radiographs (95% CI: 23.8, 32.5; 120 of 429 patients), or 7.8% (120 of 1529 patients) of all posteroanterior chest radiographs. Conclusion Of all normal posteroanterior chest radiographs, 28% were autonomously reported by AI with a sensitivity for any abnormalities higher than 99%. This corresponded to 7.8% of the entire posteroanterior chest radiograph production. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Park in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Plesner, Müller, Nybing, et al. Autonomous Chest Radiograph Reporting Using AI: Estimation of Clinical Impact. Radiology. 2023. PMID: 36880947. doi:10.1148/radiol.222268

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。