传统MRI与负重位MRI在髌股关节影像测量中的差异
结果显示站立位与仰卧位之间髌骨轨迹测量差异显著,主要与膝关节屈曲角度轻微不同有关,而非关节负荷的生理变化。作者强调负重位MRI临床使用前需标准化膝关节摆位。
要点
- 站立位与仰卧位MRI间髌骨轨迹测量差异显著,PBO差9.6%、PTA差3.1°、TT-TG差2.7 mm。
- PBO、PTA和TT-TG在跨扫描情境下可重复性最好,ICC范围0.85–0.94。
- 不同场强MRI间测量可重复性相当,但膝关节屈曲角度差异影响髌骨轨迹测量。
核心结论
- 仰卧位与站立位MRI间髌股关节重要形态学测量存在显著差异,主要由膝关节屈曲角度轻微不同引起,而非关节负荷变化。
研究设计与样本
- 采用单因素重复测量方差分析比较不同扫描情境下的测量值,通过ICC、SEM和MDC评估测量信度与一致性。
关键影像表现/征象
- 髌骨轨迹在不同扫描情境间存在差异,尤其介于3.0 T仰卧位与0.25 T站立位之间。
- 仰卧位显示膝关节轻微屈曲,站立位显示轻微过伸,平均差9.3°(P ≤ 0.001),可能与观察到的髌骨轨迹差异有关。
诊断标准与关键数值
- 髌骨二分偏移(PBO)平均差9.6%(p ≤ 0.001),髌骨倾斜角(PTA)平均差3.1°(p ≤ 0.001),胫骨结节-滑车沟距离(TT-TG)平均差2.7 mm(p ≤ 0.001),均为3.0 T仰卧位与0.25 T站立位比较。
- PBO、PTA和TT-TG跨扫描情境的信度与一致性最好,ICC范围0.85–0.94。
临床应用与阅片要点
- 阅片及报告髌股关节形态学测量时需注意扫描体位(仰卧 vs 站立)及膝关节屈曲角度对髌骨轨迹参数的影响。
- 负重位位置性MRI临床应用前应标准化膝关节摆位,以保证测量可比性。
局限性
- 不同场强(3 T vs 0.25 T)与体位同时变化,可能对测量差异存在混杂影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare radiological measurements of the patellofemoral joint (PFJ) morphology and measurement reproducibility across the following scanning modalities: (a) 3 T supine MRI, (b) 0.25 T supine MRI and (c) standing 0.25 T MRI.
METHODS: Forty patients referred to MRI of the knee were scanned by high field 3 T MRI in supine position and low field 0.25 T positional (pMRI) in supine and standing positions. Radiological measurements for assessment of femoral trochlear morphology, patellar tracking, patellar height and knee flexion angle were compared across scanning situations by one-way repeated-measures ANOVA. Measurement reliability and agreement were assessed by calculation of ICC, SEM and MDC.
RESULTS: Patellar tracking differed across scanning situations, particularly between 3.0 T supine and 0.25 T standing position. Mean differences are the following: patella bisect offset (PBO): 9.6%, p ≤ 0.001; patellar tilt angle (PTA): 3.1°, p ≤ 0.001; tibial tuberosity-trochlear groove distance (TT-TG): 2.7 mm, p ≤ 0.001). Measurements revealed slight knee joint flexion in supine and slight hyperextension in the standing position (MD: 9.3°, P ≤ 0.001), likely related to the observed differences in patellar tracking. Reproducibility was comparable across MRI field strengths. In general, PBO, PTA and TT-TG were the most robust measurements in terms of reproducibility and agreement across scanning situations (ICC range: 0.85-0.94).
CONCLUSION: Significant differences in important patellofemoral morphology measurements were observed between supine and standing MRI scanning positions. These were unlikely due to physiological factors such as changes in joint loading but rather induced by slight differences in knee flexion angle. This emphasises the need to standardise knee positioning during scanning, particularly for weight-bearing positional MRI before clinical use.
引用
- Hansen, Harving, Øhlenschlæger, et al. Comparison between conventional MRI and weight-bearing positional MRI reveals important differences in radiological measurements of the patellofemoral joint. Skeletal Radiol. 2023. PMID: 36877225. doi:10.1007/s00256-023-04304-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。