文献速递胸部CT

光谱成形超低剂量CT用于肺癌筛查:与低剂量CT的LungRADS分类一致性比较

Ultra-low dose computed tomography protocols using spectral shaping for lung cancer screening: Comparison with low-dose for volumetric LungRADS classification.
PubMed 文献 · Eur J Radiol · 2023-02-28

结果显示超低剂量CT与低剂量CT的LungRADS分类一致性极佳(κ 0.87–0.91),且ULDCT3辐射剂量最低(中位有效剂量0.27 mSv),可作为肺癌筛查的可行方案。

要点

  • 超低剂量CT与低剂量CT的LungRADS分类一致性极佳,κ值0.87–0.91。
  • ULDCT3协议辐射剂量最低(中位有效剂量0.27 mSv),且能正确识别LungRADS 4B结节。
  • 超低剂量CT在Qr49ADMIRE 4和Br49ADMIRE 3重建下均能检出87%–88%的低剂量CT主导肺结节。
英文原文(摘要)· 点击展开

PURPOSE: To compare Low-Dose Computed Tomography (LDCT) with four different Ultra-Low-Dose Computed Tomography (ULDCT) protocols for PN classification according to the Lung Reporting and Data System (LungRADS).

METHODS: Three hundred sixty-one participants of an ongoing lung cancer screening (LCS) underwent single-breath-hold double chest Computed Tomography (CT), including LDCT (120kVp, 25mAs; CTDIvol 1,62 mGy) and one ULDCT among: fully automated exposure control ("ULDCT1"); fixed tube-voltage and current according to patient size ("ULDCT2"); hybrid approach with fixed tube-voltage ("ULDCT3") and tube current automated exposure control ("ULDCT4"). Two radiologists (R1, R2) assessed LungRADS 2022 categories on LDCT, and then after 2 weeks on ULDCT using two different kernels (R1: Qr49ADMIRE 4; R2: Br49ADMIRE 3). Intra-subject agreement for LungRADS categories between LDCT and ULDCT was measured by the k-Cohen Index with Fleiss-Cohen weights.

RESULTS: LDCT-dominant PNs were detected in ULDCT in 87 % of cases on Qr49ADMIRE 4 and 88 % on Br49ADMIRE 3. The intra-subject agreement was: κULDCT1 = 0.89 [95 %CI 0.82-0.96]; κULDCT2 = 0.90 [0.81-0.98]; κULDCT3 = 0.91 [0.84-0.99]; κULDCT4 = 0.88 [0.78-0.97] on Qr49ADMIRE 4, and κULDCT1 = 0.88 [0.80-0.95]; κULDCT2 = 0.91 [0.86-0.96]; κULDCT3 = 0.87 [0.78-0.95]; and κULDCT4 = 0.88 [0.82-0.94] on Br49ADMIRE 3. LDCT classified as LungRADS 4B were correctly identified as LungRADS 4B at ULDCT3, with the lowest radiation exposure among the tested protocols (median effective doses were 0.31, 0.36, 0.27 and 0.37 mSv for ULDCT1, ULDCT2, ULDCT3, and ULDCT4, respectively).

CONCLUSIONS: ULDCT by spectral shaping allows the detection and characterization of PNs with an excellent agreement with LDCT and can be proposed as a feasible approach in LCS.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Milanese, Ledda, Sabia, et al. Ultra-low dose computed tomography protocols using spectral shaping for lung cancer screening: Comparison with low-dose for volumetric LungRADS classification. Eur J Radiol. 2023. PMID: 36878153. doi:10.1016/j.ejrad.2023.110760

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。