肩袖修复术后肌腱硬度变化的系统时间评估
本研究对50例单排倒褥式肩袖修复患者进行前瞻性超声剪切波弹性成像随访,在术后1、6、12、24、52周评估冈上肌腱硬度和厚度。结果显示肌腱愈合至骨需6周,止点处硬度在6个月时增加21%(1.32 m/s),外侧先于内侧变硬,肌腱厚度在6周时减少11%(0.6 mm)后稳定。术后1周弹性硬度较低者6周时更易变薄。
要点
- 肩袖修复术后6周内肌腱可能拉伸变薄,弹性硬度低者更明显。
- 止点处肌腱硬度在6个月时增加21%,外侧先于内侧恢复。
- 术后6周肌腱厚度减少11%后趋于稳定,无增生性愈合反应。
关键影像表现/征象
- 术后6个月止点处平均肌腱硬度增加21%(1.32 m/s),外侧肌腱先于内侧变硬。
- 术后6周肌腱厚度减少11%(0.6 mm),至24周稳定。
临床应用与阅片要点
- 术后6周内发现肌腱变薄不应轻易判为再撕裂,需结合弹性硬度动态观察。
- 弹性硬度较低者应警惕早期肌腱拉伸变薄,建议密切随访。
局限性
- 单中心、单超声医师操作,样本量50例,结果外推需谨慎。
- 仅评估单排倒褥式修复技术,不适用于其他修复方式。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: How the material properties of the human supraspinatus tendon change following arthroscopic rotator cuff repair is undetermined. Shear wave elastography ultrasound is a relatively new, noninvasive measure of tissue stiffness. We aimed to evaluate any temporal changes in stiffness and/or thickness of supraspinatus tendons in humans following primary arthroscopic rotator cuff repair.
METHODS: Shear wave elastography was performed at three predetermined regions by a single sonographer at 1-, 6-, 12-, 24-, and 52 weeks postoperatively in 50 consecutive single-row inverted mattress primary arthroscopic rotator cuff repairs. One-way ANOVA with Tukey's correction and Spearman's correlation tests was performed.
RESULTS: Of 50 patients, two retore by 1-week and were excluded. Two patients retore at 6 weeks, two at 12 weeks, and one at 24 weeks. The mean tendon stiffness in 48 patients at the tendon footprint increased by 21% (1.32 m/s) at 6 months (P < .001), with the lateral tendon stiffening before the medial tendon. Tendon thickness decreased by 11% (0.6 mm) at 6 weeks (P = .008), then stabilized to 24 weeks. Tendons that were less elastographically stiff at 1 week were more likely to be thinner at 6-weeks (r = .38, P = .010).
CONCLUSIONS: The data supports the hypothesis that rotator cuff tendons repaired using the single-row inverted-mattress technique take 6 weeks to heal to bone. Unlike in other tendons, there was no hypertrophic healing response. Prior to 6 weeks, the tendon may stretch/thin-out, particularly if its material properties, as assessed by shear wave elastography, are inferior. The material properties of the tendon improved at the tendon insertion site first, then medially out to 12 months post-repair.
引用
- Hackett, Ting, Lam, et al. A Systematic Temporal Assessment of Changes in Tendon Stiffness Following Rotator Cuff Repair. J Ultrasound Med. 2023. PMID: 36851879. doi:10.1002/jum.16201
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。