文献速递腹部介入USCT

实时虚拟超声提高毫米级肝内目标识别信心

Enhanced Recognition Confidence of Millimeter-Sized Intrahepatic Targets by Real-Time Virtual Sonography.
PubMed 文献 · J Ultrasound Med · 2023-02-22

本研究纳入55例术前薄层动态CT发现小肝内目标的患者,共117个目标(中位大小6.0mm),比较开腹后常规术中超声与实时虚拟超声(RVS)对目标的识别信心评分。RVS使识别信心评分从2.78显著提高至4.52,17个常规超声未检出目标中14个经RVS识别,小肝肿瘤检出率从81.1%提高至96.7%。

要点

  • RVS可显著提高术中超声对毫米级肝内目标的识别信心。
  • 常规术中超声未检出的小目标,多数可通过RVS识别。
  • RVS配准时间中位仅3.6秒,适合术中实时导航。

核心结论

  • RVS增强了术者对术前CT发现的毫米级肝内目标的识别信心。
  • RVS可提高常规术中超声对小肝肿瘤的检出率。

研究设计与样本

  • 前瞻性单臂研究,纳入55例术前薄层动态CT发现小肝内目标并计划肝切除的患者。
  • 共评估117个目标,包括毫米级肝肿瘤或三级及以上门静脉分支,术前用3D模拟软件在CT上标记。
  • 开腹后先后用常规术中超声和RVS搜索目标,术者以1-5分主观评分识别信心。

关键影像表现/征象

  • 目标中位大小为6.0mm,RVS配准时间中位为3.6秒。
  • 常规术中超声识别信心评分为2.78分,使用RVS后提高至4.52分。
  • 17个目标(14.5%)在常规术中超声中未检出,其中14个经RVS识别。

诊断标准与关键数值

  • 识别信心采用1-5分主观评分,5分为最高信心检出,1分为无法检出。
  • 小肝肿瘤(识别信心2-5分)检出率常规术中超声为81.1%,RVS为96.7%。

临床应用与阅片要点

  • 对于术前CT发现但常规术中超声难以定位的毫米级肝内目标,可考虑使用RVS辅助导航。
  • RVS可帮助识别常规超声易漏检的小肝肿瘤及深部门静脉分支。

局限性

  • 识别信心评分为术者主观评分,非客观病理金标准验证。
  • 单中心研究,样本量有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Real-time virtual sonography (RVS) is an artificial-intelligence-assisted ultrasonographic navigation system that displays synchronized preoperative computed tomography (CT) images corresponding to real-time intraoperative ultrasonograms (IOUS). This study aimed to investigate whether RVS can enhance IOUS identification of small intrahepatic targets found in preoperative CT.

METHODS: Patients with small intrahepatic targets detected by preoperative thin-slice dynamic CT before liver resection were included. The targets included millimeter-sized liver tumors or a third-order or more distal portal branch and were marked on CT images using 3D simulation software. After laparotomy, the targets were searched using fundamental IOUS, and participating liver surgeons subjectively scored the target identifying confidence on a scale of 1-5 (5 points for detection with the highest confidence and one point for undetectable). Then, the search procedure was repeated using the RVS, and the scores were compared.

RESULTS: Totally, 55 patients with 117 small targets were investigated. The median target size was 6.0 mm, and the median registration time was 3.6 seconds. The target identification confidence score significantly increased from 2.78 to 4.52 points after using RVS. Seventeen targets (14.5%) were undetectable in fundamental IOUS, and 14 of them were identified by RVS. The detectability of small liver tumors (2-5 points of identification confidence) by IOUS was 81.1 and 96.7% by RVS.

CONCLUSION: RVS enhanced surgeons' confidence in identifying millimeter-sized intrahepatic targets found in preoperative CT.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Takamoto, Nara, Ban, et al. Enhanced Recognition Confidence of Millimeter-Sized Intrahepatic Targets by Real-Time Virtual Sonography. J Ultrasound Med. 2023. PMID: 36814362. doi:10.1002/jum.16199

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。