文献速递骨肌MR

长距离跑步后膝关节软骨与半月板的超短回波磁化传递成像

Ultrashort echo time magnetization transfer imaging of knee cartilage and meniscus after long-distance running.
PubMed 文献 · Eur Radiol · 2023-02-23

这项前瞻性队列研究纳入23名业余马拉松跑者(46膝),在赛前、赛后2天和赛后4周使用3D超短回波磁化传递(UTE-MT)及UTE-T2*序列成像。UTE-MTR在多数软骨和半月板亚区赛后2天降低、休息4周后回升,且变化较UTE-T2*更敏感。结论认为UTE-MTR是检测长距离跑步后膝软骨和半月板动态变化的有前景方法。

要点

  • UTE-MTR在赛后2天下降、4周后恢复,可动态反映软骨和半月板变化。
  • 软骨三个亚区(外侧胫骨平台、内侧股骨髁中部、内侧胫骨平台)UTE-MTR显著降低。
  • 半月板内侧后角和外侧后角UTE-MTR在赛后2天显著降低。

关键影像表现/征象

  • 多数软骨和半月板亚区UTE-MTR值在赛后2天降低、休息4周后升高,UTE-T2*值则赛后2天升高、4周后降低。
  • 外侧胫骨平台、内侧股骨髁中部和内侧胫骨平台的UTE-MTR在赛后2天较另外两个时间点显著降低(p < 0.05)。
  • 半月板内侧后角和外侧后角UTE-MTR在赛后2天显著低于赛前和4周后(p < 0.05)。
  • 任何软骨亚区的UTE-T2*均未见显著变化,半月板仅内侧后角UTE-T2*有显著差异。

临床应用与阅片要点

  • UTE-MTR可用于无创监测长距离跑步后膝软骨和半月板的动态变化,阅片时注意赛后2天为变化窗口。
  • 软骨重点观察外侧胫骨平台、内侧股骨髁中部和内侧胫骨平台,半月板重点观察内、外侧后角。
  • UTE-MTR对软骨变化的敏感性高于UTE-T2*,报告时可优先参考UTE-MTR。

局限性

  • 样本量较小(23名跑者,46膝),可能影响结果的普遍性。
  • 仅评估业余马拉松跑者,结论外推至其他人群需谨慎。
  • 随访时间点有限(赛前、赛后2天、赛后4周),未覆盖更长期变化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the detection of changes in knee cartilage and meniscus of amateur marathon runners before and after long-distance running using a 3D ultrashort echo time MRI sequence with magnetization transfer preparation (UTE-MT).

METHODS: We recruited 23 amateur marathon runners (46 knees) in this prospective cohort study. MRI scans using UTE-MT and UTE-T2* sequences were performed pre-race, 2 days post-race, and 4 weeks post-race. UTE-MT ratio (UTE-MTR) and UTE-T2* were measured for knee cartilage (eight subregions) and meniscus (four subregions). The sequence reproducibility and inter-rater reliability were also investigated.

RESULTS: Both the UTE-MTR and UTE-T2* measurements showed good reproducibility and inter-rater reliability. For most subregions of cartilage and meniscus, the UTE-MTR values decreased 2 days post-race and increased after 4 weeks of rest. Conversely, the UTE-T2* values increased 2 days post-race and decreased after 4 weeks. The UTE-MTR values in lateral tibial plateau, central medial femoral condyle, and medial tibial plateau showed a significant decrease at 2 days post-race compared to the other two time points (p < 0.05). By comparison, no significant UTE-T2* changes were found for any cartilage subregions. For meniscus, the UTE-MTR values in medial posterior horn and lateral posterior horn regions at 2 days post-race were significantly lower than those at pre-race and 4 weeks post-race (p < 0.05). By comparison, only the UTE-T2* values in medial posterior horn showed a significant difference.

CONCLUSIONS: UTE-MTR is a promising method for the detection of dynamic changes in knee cartilage and meniscus after long-distance running.

KEY POINTS: • Long-distance running causes changes in the knee cartilage and meniscus. • UTE-MT monitors dynamic changes of knee cartilage and meniscal non-invasively. • UTE-MT is superior to UTE-T2* in monitoring dynamic changes in knee cartilage and meniscus.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Zhu, Wu, Yu, et al. Ultrashort echo time magnetization transfer imaging of knee cartilage and meniscus after long-distance running. Eur Radiol. 2023. PMID: 36814033. doi:10.1007/s00330-023-09462-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。