文献速递乳腺US

基于线性回归建模的评分系统:联合彩色多普勒与剪切波弹性成像减少乳腺良性活检

Linear Regression Modeling Based Scoring System to Reduce Benign Breast Biopsies Using Multi-parametric US with Color Doppler and SWE.
PubMed 文献 · Acad Radiol · 2023-02-16

本研究纳入BI-RADS 4或5类乳腺病灶,利用常规超声、彩色多普勒及剪切波弹性成像参数建立线性回归评分系统,并在另一中心187例BI-RADS 3-5类病灶中验证。评分系统可避免37.8%良性病灶活检,漏诊1.1%恶性病灶;验证集阴性预测值100%,特异度74.6%。

要点

  • 联合US+SWE参数的线性回归模型AUC达0.882,优于单一参数。
  • 评分系统可减少37.8%良性活检,仅漏诊1.1%恶性。
  • 外部验证阴性预测值100%,特异度74.6%。

核心结论

  • 基于US+SWE参数的线性回归评分系统可显著减少乳腺良性病灶活检,且漏诊恶性比例低。

研究设计与样本

  • 前瞻性或回顾性研究(原文未明确),纳入418个BI-RADS 4或5类乳腺病灶(238良性,180恶性),活检前行SWE检查。
  • 另用另一中心187例BI-RADS 3、4、5类病灶进行外部验证。
  • 采用决策树将连续参数转为分类变量,逐步回归建立线性回归模型并确定最优系数。

诊断标准与关键数值

  • US和CDUS参数鉴别良恶性AUC为0.592-0.696,SWE参数AUC为0.607-0.816。
  • US+CDUS模型AUC为0.819,US+SWE模型AUC为0.882。
  • 评分系统避免37.8%良性病灶活检,漏诊1.1%恶性病灶;验证集NPV 100%,特异度74.6%。

临床应用与阅片要点

  • 对BI-RADS 4或5类病灶,可结合SWE参数(如SWVMin、SWVMax、SWVH、SWVR、SWVRn)及大小比进行评分,辅助决定是否活检。
  • 评分系统在验证集中NPV达100%,但需注意其特异度74.6%,假阳性仍存在。

局限性

  • 原文未明确报告研究设计类型及样本量估算。
  • 验证集包含BI-RADS 3类病灶,与建模集(仅4或5类)人群存在差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To develop a simple ultrasound (US) based scoring system to reduce benign breast biopsies.

MATERIALS AND METHODS: Women with BI-RADS 4 or 5 breast lesions underwent shear-wave elastography (SWE) imaging before biopsy. Standard US and color Doppler US (CDUS) parameters were recorded, and the size ratio (SzR=longest/shortest diameter) was calculated. Measured/calculated SWE parameters were minimum (SWVMin) and maximum (SWVMax) shear velocity, velocity heterogeneity (SWVH=SWVMax-SWVMin), velocity ratio (SWVR=SWVMin/SWVMax), and normalized SWVR (SWVRn=(SWVMax-SWVMin)/SWVMin). Linear regression analysis was performed by converting continuous parameters into categorical corresponding equivalents using decision tree analyses. Linear regression models were fitted using stepwise regression analysis and optimal coefficients for the predictors in the models were determined. A scoring model was devised from the results and validated using a different data set from another center consisting of 187 cases with BI-RADS 3, 4, and 5 lesions.

RESULTS: A total of 418 lesions (238 benign, 180 malignant) were analyzed. US and CDUS parameters exhibited poor (AUC=0.592-0.696), SWE parameters exhibited poor-good (AUC=0.607-0.816) diagnostic performance in benign/malignant discrimination. Linear regression models of US+CDUS and US+SWE parameters revealed an AUC of 0.819 and 0.882, respectively. The developed scoring system could have avoided biopsy in 37.8% of benign lesions while missing 1.1% of malignant lesions. The scoring system was validated with a 100% NPV rate with a specificity of 74.6%.

CONCLUSION: The linear regression model using US+SWE parameters performed better than any single parameter alone. The developed scoring method could lead to a significant decrease in benign biopsies.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Demirci, Buğdaycı, Ertaş, et al. Linear Regression Modeling Based Scoring System to Reduce Benign Breast Biopsies Using Multi-parametric US with Color Doppler and SWE. Acad Radiol. 2023. PMID: 36804295. doi:10.1016/j.acra.2023.01.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。