PubMed 文献 · Ultrasound Med Biol · 2023-02-19

HAPIN试验在危地马拉、秘鲁和卢旺达的婴儿中采用肺部超声确认重症肺炎临床诊断,制定了标准化肺炎定义、超声医师招募培训方案及图像采集判读流程,并采用盲法判读小组(两名不知情超声医师加专家仲裁)进行质控。共采集357次肺部超声扫描,主要终点肺炎(PEP)诊断需专家仲裁的扫描占39%,PEP诊断率为40%,两名盲法判读者与专家之间的一致率在三国分别为65%、62%和67%,校正kappa值分别为0.30、0.24和0.33。标准化影像方案、培训和仲裁小组使肺部超声诊断肺炎具有高置信度。

要点

  • 肺部超声可替代胸片用于肺炎诊断,但需标准化采集和判读流程。
  • 采用盲法判读加专家仲裁的质控方式,PEP诊断一致率约62%–67%,kappa值0.24–0.33。
  • 约39%的扫描需专家仲裁,提示判读一致性中等,仲裁机制对研究质控重要。

关键影像表现/征象

  • 主要终点肺炎(PEP)诊断在141次扫描(40%)中成立,213次(60%)不成立,3次(<1%)无法判读。
  • 181次扫描(39%)的PEP诊断需要专家仲裁。

诊断标准与关键数值

  • 两名盲法判读者与专家在危地马拉、秘鲁和卢旺达的一致率分别为65%、62%和67%,患病率偏倚校正kappa值分别为0.30、0.24和0.33。
  • PEP诊断需专家仲裁的扫描占39%,无法判读的扫描占<1%。

临床应用与阅片要点

  • 肺部超声诊断肺炎应采用标准化图像采集和判读流程,并设置盲法判读与专家仲裁机制以提高置信度。
  • 判读一致性中等(kappa 0.24–0.33),提示需重视培训与质控,仲裁结果应作为参考标准。

局限性

  • 原文未明确报告研究设计类型为回顾性或前瞻性,也未报告样本量计算或效能分析。
  • 秘鲁仅采集8次扫描,样本量远低于其他两国,可能影响该国一致性估计的稳定性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Lung ultrasound (LUS) is an alternative to chest radiography to confirm a diagnosis of pneumonia. For research and disease surveillance, methods to use LUS to diagnose pneumonia are needed.

METHODS: In the Household Air Pollution Intervention Network (HAPIN) trial, LUS was used to confirm a clinical diagnosis of severe pneumonia in infants. We developed a standardized definition of pneumonia, protocols for recruitment and training of sonographers, along with LUS image acquisition and interpretation. We use a blinded panel approach to interpretation with LUS cine-loops randomized to non-scanning sonographers with expert review.

DISCUSSION: We obtained 357 lung ultrasound scans: 159, 8 and 190 scans were collected in Guatemala, Peru and Rwanda, respectively. The diagnosis of primary endpoint pneumonia (PEP) required an expert tie breaker in 181 scans (39%). PEP was diagnosed in 141 scans (40%), not diagnosed in 213 (60%), with 3 scans (<1%) deemed uninterpretable. Agreement among the two blinded sonographers and the expert reader in Guatemala, Peru and Rwanda was 65%, 62% and 67%, with a prevalence-and-bias-corrected kappa of 0.30, 0.24 and 0.33, respectively.

CONCLUSION: Use of standardized imaging protocols, training and an adjudication panel resulted in high confidence for the diagnosis of pneumonia using LUS.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Simkovich, Hossen, McCollum, et al. Lung Ultrasound Protocol and Quality Control of Image Interpretation Using an Adjudication Panel in the Household Air Pollution Intervention Network (HAPIN) Trial. Ultrasound Med Biol. 2023. PMID: 36801180. doi:10.1016/j.ultrasmedbio.2023.01.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。