文献速递心血管CTDSA

深度学习辅助冠脉CTA对冠心病的诊断效能:多阅片者多病例研究

Diagnostic performance of deep learning-based vessel extraction and stenosis detection on coronary computed tomography angiography for coronary artery disease: a multi-reader multi-case study.
PubMed 文献 · Radiol Med · 2023-02-17

本研究纳入5个中心374例病例、12名放射科医生,以侵入性冠状动脉造影为参考标准,评估深度学习系统辅助诊断阻塞性冠心病的效能。结果显示,DL辅助使患者水平AUC从0.81提升至0.82、血管水平从0.79提升至0.81,经验不足者提升明显;后处理与报告时间从798.60秒降至189.12秒。

要点

  • DL辅助可缩短CCTA后处理与报告时间至约189秒
  • DL辅助提升整体诊断AUC,经验不足者获益更明显
  • DL单独使用敏感度高但特异度有限,需结合人工判读

核心结论

  • DL系统作为同步阅片者时,整体后处理与阅片时间显著缩短,人工阅片者诊断准确度提升,尤其对经验不足者。

研究设计与样本

  • 多阅片者多病例研究,纳入5个中心374例病例,邀请12名放射科医生,以侵入性冠状动脉造影为参考标准。

诊断标准与关键数值

  • 无DL辅助时患者水平AUC为0.81,有DL辅助时提升至0.82(p < 0.05)。
  • 无DL辅助时血管水平AUC为0.79,有DL辅助时提升至0.81(p < 0.05)。
  • DL系统单独使用时患者水平敏感度93.55%、特异度59.57%。
  • DL系统单独使用时血管水平敏感度83.23%、特异度79.97%。
  • DL系统对比人工阅片者,平均后处理与报告时间从798.60秒降至189.12秒(p < 0.05)。

临床应用与阅片要点

  • 可将DL系统作为同步阅片工具,用于缩短CCTA后处理和报告时间。
  • 经验不足的放射科医生可借助DL辅助提升诊断准确度,经验丰富者AUC未见显著提升。
  • DL单独使用时患者水平特异度仅59.57%,不宜脱离人工判读单独用于排除阻塞性冠心病。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Post-processing and interpretation of coronary CT angiography (CCTA) imaging are time-consuming and dependent on the reader's experience. An automated deep learning (DL)-based imaging reconstruction and diagnosis system was developed to improve diagnostic accuracy and efficiency.

METHODS: Our study including 374 cases from five sites, inviting 12 radiologists, assessed the DL-based system in diagnosing obstructive coronary disease with regard to diagnostic performance, imaging post-processing and reporting time of radiologists, with invasive coronary angiography as a standard reference. The diagnostic performance of DL system and DL-assisted human readers was compared with the traditional method of human readers without DL system.

RESULTS: Comparing the diagnostic performance of human readers without DL system versus with DL system, the AUC was improved from 0.81 to 0.82 (p < 0.05) at patient level and from 0.79 to 0.81 (p < 0.05) at vessel level. An increase in AUC was observed in inexperienced radiologists (p < 0.05), but was absent in experienced radiologists. Regarding diagnostic efficiency, comparing the DL system versus human reader, the average post-processing and reporting time was decreased from 798.60 s to 189.12 s (p < 0.05). The sensitivity and specificity of using DL system alone were 93.55% and 59.57% at patient level and 83.23% and 79.97% at vessel level, respectively.

CONCLUSIONS: With the DL system serving as a concurrent reader, the overall post-processing and reading time was substantially reduced. The diagnostic accuracy of human readers, especially for inexperienced readers, was improved. DL-assisted human reader had the potential of being the reading mode of choice in clinical routine.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Yang, Chen, Yang, et al. Diagnostic performance of deep learning-based vessel extraction and stenosis detection on coronary computed tomography angiography for coronary artery disease: a multi-reader multi-case study. Radiol Med. 2023. PMID: 36800112. doi:10.1007/s11547-023-01606-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。