文献速递神经儿科影像MR

儿童脊髓拴系评估中VIBE/LAVA与T1 FSE对椎管内脂肪病变诊断效能的比较

Diagnostic Utility of 3D Gradient-Echo MR Imaging Sequences through the Filum Compared with Spin-Echo T1 in Children with Concern for Tethered Cord.
PubMed 文献 · AJNR Am J Neuroradiol · 2023-02-16

结论提示3D梯度回波序列虽运动不敏感,但可能漏诊小的椎管内脂肪病变。

要点

  • 评估儿童脊髓拴系时,T1 FSE序列对椎管内脂肪病变的检出率(95%)远高于VIBE/LAVA(55%)。
  • 对于疑似椎管内脂肪病变,应优先使用T1 FSE序列,3D梯度回波序列可能漏诊小病变。
  • VIBE/LAVA测得的脂肪病变尺寸显著小于T1 FSE,可能低估病变范围。

关键影像表现/征象

  • T1 FSE序列显示脂肪病变在21/22例(95%)中可见,而VIBE/LAVA仅在12/22例(55%)中检出。

诊断标准与关键数值

  • T1 FSE对椎管内脂肪病变的检出率为95%(21/22),VIBE/LAVA为55%(12/22)。
  • VIBE/LAVA可检测的最小脂肪病变尺寸通过ROC曲线确定(原文未报告具体阈值)。

临床应用与阅片要点

  • 在儿童脊髓拴系评估中,应优先使用T1 FSE序列检测椎管内脂肪病变。
  • 当使用VIBE/LAVA等3D梯度回波序列时,需警惕其可能漏诊小的脂肪病变,尤其对于可疑病例应加做T1 FSE。

局限性

  • 本研究为回顾性、单中心设计,可能存在选择偏倚。
  • VIBE/LAVA和T1 FSE的评估间隔数周,但未提及评估者间一致性分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Fatty intrathecal lesions are a cause of tethered cord, and detection of these on spinal MR imaging is paramount. Conventional T1 FSE sequences are the mainstay of detecting fatty elements; however, 3D gradient-echo MR images, volumetric interpolated breath-hold examination/liver acquisition with volume acceleration (VIBE/LAVA), are popular, given the increased motion resistance. We sought to evaluate the diagnostic accuracy of VIBE/LAVA compared with T1 FSE for detection of fatty intrathecal lesions.

MATERIALS AND METHODS: In this retrospective, institutional review board-approved study, 479 consecutive pediatric spine MRIs obtained to evaluate cord tethering between January 2016 and April 2022 were reviewed. Inclusion criteria were patients who were 20 years of age or younger who underwent spine MRIs containing both axial T1 FSE and VIBE/LAVA sequences of the lumbar spine. The presence or absence of fatty intrathecal lesions was recorded for each sequence. If fatty intrathecal lesions were present, anterior-posterior and transverse dimensions were recorded. VIBE/LAVA and T1 FSE sequences were evaluated on 2 separate occasions (VIBE/LAVAs first followed by T1 FSE several weeks later) to minimize bias. Basic descriptive statistics compared fatty intrathecal lesion sizes on T1 FSEs and VIBE/LAVAs. Receiver operating characteristic curves were used to determine minimal fatty intrathecal lesion size detectable by VIBE/LAVA.

RESULTS: Sixty-six patients were included, with 22 having fatty intrathecal lesions (mean age, 7.2 years). T1 FSE sequences revealed fatty intrathecal lesions in 21/22 cases (95%); however, fatty intrathecal lesions on VIBE/LAVA were detected in 12/22 patients (55%). Mean anterior-posterior and transverse dimensions of fatty intrathecal lesions measured larger on T1 FSE compared with VIBE/LAVA sequences (5.4 × 5.0 mm versus 1.5 × 1.6 mm, respectively; P values = .039 anterior-posterior; .027 transverse).

CONCLUSIONS: While T1 3D gradient-echo MR images may have decreased the acquisition time and are more motion-resistant than conventional T1 FSE sequences, they are less sensitive and may miss small fatty intrathecal lesions.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Rafiee, Mehan, Rincon, et al. Diagnostic Utility of 3D Gradient-Echo MR Imaging Sequences through the Filum Compared with Spin-Echo T1 in Children with Concern for Tethered Cord. AJNR Am J Neuroradiol. 2023. PMID: 36797030. doi:10.3174/ajnr.A7791

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。