文献速递神经MR

基于全脑灰质功能与结构的影像组学方法自动分类MSA亚型

Automatic classification of MSA subtypes using Whole-brain gray matter function and Structure-Based radiomics approach.
PubMed 文献 · Eur J Radiol · 2023-02-10

本研究纳入30例MSA-C和41例MSA-P内部队列及11例MSA-C和10例MSA-P外部测试队列,从3D-T1和静息态fMRI提取7308个灰质体积及功能特征,经t检验和Lasso筛选出12个特征,用SVM、随机森林和逻辑回归分类。随机森林模型在验证集和测试集AUC分别为0.91和0.80,小脑、眶额叶和边缘系统的功能活动与连接是区分MSA亚型的重要特征。

要点

  • 随机森林模型区分MSA-C与MSA-P的验证集AUC为0.91、测试集AUC为0.80。
  • 筛选出的12个特征中10个为静息态功能连接,1个ALFF和1个DC。
  • 小脑、眶额叶和边缘系统的功能活动与连接是区分MSA亚型的关键。

关键影像表现/征象

  • 小脑、眶额叶和边缘系统的脑功能活动与连接是区分MSA亚型的重要特征。
  • 筛选出的12个特征包括1个ALFF、1个DC和10个RSFC。

诊断标准与关键数值

  • 随机森林模型在验证集和测试集的AUC分别为0.91和0.80。
  • 所有分类器均表现出显著的分类性能,尤以随机森林模型为著。

临床应用与阅片要点

  • 日常阅片时可关注小脑、眶额叶和边缘系统的功能活动与连接改变,辅助区分MSA-P与MSA-C。
  • 影像组学模型可作为临床诊断系统的辅助工具,但需注意外部测试集AUC低于验证集,提示泛化性能有限。

局限性

  • 外部测试队列样本量较小(MSA-C 11例、MSA-P 10例)。
  • 研究为单中心内部队列加外部测试设计,未报告多中心验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: This study aims to develop a radiomics method based on the function and structure of whole-brain gray matter to accurately classify multiple system atrophy with predominant Parkinsonism (MSA-P) or predominant cerebellar ataxia (MSA-C).

METHODS: We enrolled 30 MSA-C and 41 MSA-P cases for the internal cohort and 11 MSA-C and 10 MSA-P cases for the external test cohort. We extracted 7,308 features, including gray matter volume (GMV), mean amplitude of low-frequency fluctuation (mALFF), mean regional homogeneity (mReHo), degree of centrality (DC), voxel-mirrored homotopic connectivity (VMHC), and resting-state functional connectivity (RSFC) from 3D-T1 and Rs-fMR data. Feature selection was conducted with t-test and least absolute shrinkage and selection operator (Lasso). Classification was performed using the support vector machine with linear and RBF kernel (SVM-linear/SVM-RBF), random forest and logistic regression. Model performance was assessed via receiver operating characteristic (ROC) curve and compared with DeLong's test.

RESULTS: Feature selection resulted in 12 features, including 1 ALFF, 1 DC and 10 RSFC. All the classifiers showed remarkable classification performance, especially the RF model which exhibited AUC values of 0.91 and 0.80 in the validation and test datasets, respectively. The brain functional activity and connectivity in the cerebellum, orbitofrontal lobe and limbic system were important features to distinguish MSA subtypes with the same disease severity and duration.

CONCLUSION: Radiomics approach has the potential to support clinical diagnostic systems and to achieve high classification accuracy for distinguishing between MSA-C and MSA-P patients at the individual level.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Chen, He, Xu, et al. Automatic classification of MSA subtypes using Whole-brain gray matter function and Structure-Based radiomics approach. Eur J Radiol. 2023. PMID: 36796145. doi:10.1016/j.ejrad.2023.110735

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。