文献速递胸部技术与安全DR

人工智能辅助与常规胸部X线判读在急诊急性呼吸道症状患者中的实用随机临床试验

Conventional Versus Artificial Intelligence-Assisted Interpretation of Chest Radiographs in Patients With Acute Respiratory Symptoms in Emergency Department: A Pragmatic Randomized Clinical Trial.
PubMed 文献 · Korean J Radiol · 2023-02-06

该实用随机临床试验在急诊急性呼吸道症状患者中比较AI-CAD辅助与常规判读胸部X线的准确性。共随机分配3576例,主要结局敏感度在干预组67.2%、对照组66.0%(OR 1.02,95%CI 0.70-1.49,P=0.917),假阳性率19.3% vs 18.5%(P=0.985)。结论:AI-CAD未改善值班放射科医师判读的敏感度和假阳性率。

要点

  • AI-CAD辅助未提高急诊胸片判读敏感度(67.2% vs 66.0%)。
  • AI-CAD辅助未降低假阳性率(19.3% vs 18.5%)。
  • 参考标准为急诊就诊至少30天后的病历回顾。

核心结论

  • AI-CAD辅助未改善值班放射科医师判读胸片诊断急性胸部疾病的敏感度和假阳性率。

研究设计与样本

  • 实用随机临床试验,纳入急诊急性呼吸道症状行胸片患者3576例,干预组1761例、对照组1815例,单中心三级转诊机构。
  • 使用商业AI-CAD系统(Lunit INSIGHT CXR,版本2.0.2.0;Lunit Inc.),其他临床实践按标准流程。
  • 主要结局为值班放射科医师判读胸片诊断急性胸部疾病的敏感度,次要结局为假阳性率;参考标准基于急诊就诊至少30天后的病历回顾。

诊断标准与关键数值

  • 敏感度:干预组67.2%(317/472),对照组66.0%(324/491),OR 1.02(95%CI 0.70-1.49),P=0.917。
  • 假阳性率:干预组19.3%(249/1289),对照组18.5%(245/1324),OR 1.00(95%CI 0.79-1.26),P=0.985。

临床应用与阅片要点

  • 在急诊胸片判读中,AI-CAD辅助未显示可改善值班放射科医师诊断敏感度或假阳性率,日常报告不应依赖AI-CAD提高急性胸部疾病检出。

局限性

  • 单中心研究,结果外推需谨慎。
  • 参考标准基于至少30天后病历回顾,可能存在疾病状态演变或记录偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: It is unknown whether artificial intelligence-based computer-aided detection (AI-CAD) can enhance the accuracy of chest radiograph (CR) interpretation in real-world clinical practice. We aimed to compare the accuracy of CR interpretation assisted by AI-CAD to that of conventional interpretation in patients who presented to the emergency department (ED) with acute respiratory symptoms using a pragmatic randomized controlled trial.

MATERIALS AND METHODS: Patients who underwent CRs for acute respiratory symptoms at the ED of a tertiary referral institution were randomly assigned to intervention group (with assistance from an AI-CAD for CR interpretation) or control group (without AI assistance). Using a commercial AI-CAD system (Lunit INSIGHT CXR, version 2.0.2.0; Lunit Inc.). Other clinical practices were consistent with standard procedures. Sensitivity and false-positive rates of CR interpretation by duty trainee radiologists for identifying acute thoracic diseases were the primary and secondary outcomes, respectively. The reference standards for acute thoracic disease were established based on a review of the patient's medical record at least 30 days after the ED visit.

RESULTS: We randomly assigned 3576 participants to either the intervention group (1761 participants; mean age ± standard deviation, 65 ± 17 years; 978 males; acute thoracic disease in 472 participants) or the control group (1815 participants; 64 ± 17 years; 988 males; acute thoracic disease in 491 participants). The sensitivity (67.2% [317/472] in the intervention group vs. 66.0% [324/491] in the control group; odds ratio, 1.02 [95% confidence interval, 0.70-1.49]; P = 0.917) and false-positive rate (19.3% [249/1289] vs. 18.5% [245/1324]; odds ratio, 1.00 [95% confidence interval, 0.79-1.26]; P = 0.985) of CR interpretation by duty radiologists were not associated with the use of AI-CAD.

CONCLUSION: AI-CAD did not improve the sensitivity and false-positive rate of CR interpretation for diagnosing acute thoracic disease in patients with acute respiratory symptoms who presented to the ED.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Hwang, Goo, Nam, et al. Conventional Versus Artificial Intelligence-Assisted Interpretation of Chest Radiographs in Patients With Acute Respiratory Symptoms in Emergency Department: A Pragmatic Randomized Clinical Trial. Korean J Radiol. 2023. PMID: 36788769. doi:10.3348/kjr.2022.0651

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。