基于低剂量CT的序数影像组学模型预测浸润性非黏液性肺腺癌分化分级
本研究构建了基于低剂量CT的影像组学模型,用于预测浸润性非黏液性肺腺癌的分化分级,并在验证队列中与定量语义模型及放射科医生比较诊断性能。结果显示影像组学模型在验证队列中AUC达0.900和0.929,准确率0.803,与放射科专家相当,优于定量语义模型和低年资放射科医生。
要点
- 低剂量CT影像组学模型可预测浸润性非黏液性肺腺癌分化分级,性能与放射科专家相当。
- 模型在验证队列中区分Grade 1 vs. Grade 2/3的AUC为0.900,区分Grade 1/2 vs. Grade 3的AUC为0.929。
- 模型优于定量语义模型和低年资放射科医生,有助于指导随访或手术策略。
局限性
- 原文未明确报告研究局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To construct a radiomic model of low-dose CT (LDCT) to predict the differentiation grade of invasive non-mucinous pulmonary adenocarcinoma (IPA) and compare its diagnostic performance with quantitative-semantic model and radiologists.
METHODS: A total of 682 pulmonary nodules were divided into the primary cohort (181 grade 1; 254 grade 2; 64 grade 3) and validation cohort (69 grade 1; 99 grade 2; 15 grade 3) according to scanners. The radiomic and quantitative-semantic models were built using ordinal logistic regression. The diagnostic performance of the models and radiologists was assessed by the area under the curve (AUC) of the receiver operating characteristic curve and accuracy.
RESULTS: The radiomic model demonstrated excellent diagnostic performance in the validation cohort (AUC, 0.900 (95%CI: 0.847-0.939) for Grade 1 vs. Grade 2/Grade 3; AUC, 0.929 (95%CI: 0.882-0.962) for Grade 1/Grade 2 vs. Grade 3; accuracy, 0.803 (95%CI: 0.737-0.857)). No significant difference in diagnostic performance was found between the radiomic model and radiological expert (AUC, 0.840 (95%CI: 0.779-0.890) for Grade 1 vs. Grade 2/Grade 3, p = 0.130; AUC, 0.852 (95%CI: 0.793-0.900) for Grade 1/Grade 2 vs. Grade 3, p = 0.170; accuracy, 0.743 (95%CI: 0.673-0.804), p = 0.079), but the radiomic model outperformed the quantitative-semantic model and inexperienced radiologists (all p < 0.05).
CONCLUSIONS: The radiomic model of LDCT can be used to predict the differentiation grade of IPA in lung cancer screening, and its diagnostic performance is comparable to that of radiological expert.
KEY POINTS: • Early identifying the novel differentiation grade of invasive non-mucinous pulmonary adenocarcinoma may provide guidance for further surveillance, surgical strategy, or more adjuvant treatment. • The diagnostic performance of the radiomic model is comparable to that of a radiological expert and superior to that of the quantitative-semantic model and inexperienced radiologists. • The radiomic model of low-dose CT can be used to predict the differentiation grade of invasive non-mucinous pulmonary adenocarcinoma in lung cancer screening.
引用
- Li, Liu, Yang, et al. An ordinal radiomic model to predict the differentiation grade of invasive non-mucinous pulmonary adenocarcinoma based on low-dose computed tomography in lung cancer screening. Eur Radiol. 2023. PMID: 36790469. doi:10.1007/s00330-023-09453-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。