文献速递胸部CT

基于深度学习的胸部CT肺功能预测

Deep Learning-based Approach to Predict Pulmonary Function at Chest CT.
PubMed 文献 · Radiology · 2023-02-14

在时间独立测试集(n=2720)中,FVC和FEV1的平均绝对误差均为0.22 L,一致性相关系数分别为0.94和0.91;预测呼吸高风险组的准确率分别为89.6%、85.9%和90.2%,但敏感度较低。

要点

  • 深度学习模型可从低剂量胸部CT较准确预测FVC和FEV1,一致性相关系数达0.91–0.94。
  • 预测呼吸高风险组的准确率较高(85.9%–90.2%),但敏感度偏低(36.1%–61.6%)。
  • 该模型有望在肺癌筛查CT中附加肺功能评估,但需注意漏诊高风险者的可能。

核心结论

  • 深度学习模型应用于容积胸部CT可预测肺功能,性能相对较好。

研究设计与样本

  • 所有参与者同日接受低剂量CT和肺量计肺功能检查,以肺量计为参考标准。
  • 训练卷积神经网络从低剂量CT预测第一秒用力呼气容积(FEV1)和用力肺活量(FVC)。
  • 采用平均绝对误差和一致性相关系数(CCC)评估预测值与肺量计参考值之间的一致性。

诊断标准与关键数值

  • 以FVC占预计值百分比(FVC%)和FEV1占预计值百分比(FEV1%)小于80%、第一秒呼出FVC百分比(FEV1/FVC)小于70%定义呼吸高风险组。
  • 在时间独立测试集中,FVC预测的平均绝对误差为0.22 L,CCC为0.94;FEV1预测的平均绝对误差为0.22 L,CCC为0.91。
  • 预测FVC%高风险组的准确率为89.6%(2436/2720,95% CI:88.4–90.7),敏感度为61.6%(242/393,95% CI:59.7–63.4)。
  • 预测FEV1%高风险组的准确率为85.9%(2337/2720,95% CI:84.6–87.2),敏感度为46.9%(226/482,95% CI:45.0–48.8)。
  • 预测FEV1/FVC高风险组的准确率为90.2%(2453/2720,95% CI:89.1–91.3),敏感度为36.1%(91/252,95% CI:34.3–37.9)。

临床应用与阅片要点

  • 在低剂量肺癌筛查CT中可附加肺功能预测,辅助识别肺功能异常高风险者。
  • 模型预测高风险组的敏感度较低,阅片时不应仅依赖预测结果排除肺功能异常。
  • 预测值基于特定人群和扫描协议,跨设备或跨人群应用时需重新验证。

局限性

  • 回顾性单中心研究,外部推广性有限。
  • 原文未报告特异度、AUC等完整诊断性能指标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Low-dose chest CT screening is recommended for smokers with the potential for lung function abnormality, but its role in predicting lung function remains unclear. Purpose To develop a deep learning algorithm to predict pulmonary function with low-dose CT images in participants using health screening services. Materials and Methods In this retrospective study, participants underwent health screening with same-day low-dose CT and pulmonary function testing with spirometry at a university affiliated tertiary referral general hospital between January 2015 and December 2018. The data set was split into a development set (model training, validation, and internal test sets) and temporally independent test set according to first visit year. A convolutional neural network was trained to predict the forced expiratory volume in the first second of expiration (FEV1) and forced vital capacity (FVC) from low-dose CT. The mean absolute error and concordance correlation coefficient (CCC) were used to evaluate agreement between spirometry as the reference standard and deep-learning prediction as the index test. FVC and FEV1 percent predicted (hereafter, FVC% and FEV1%) values less than 80% and percent of FVC exhaled in first second (hereafter, FEV1/FVC) less than 70% were used to classify participants at high risk. Results A total of 16 148 participants were included (mean age, 55 years ± 10 [SD]; 10 981 men) and divided into a development set (n = 13 428) and temporally independent test set (n = 2720). In the temporally independent test set, the mean absolute error and CCC were 0.22 L and 0.94, respectively, for FVC and 0.22 L and 0.91 for FEV1. For the prediction of the respiratory high-risk group, FVC%, FEV1%, and FEV1/FVC had respective accuracies of 89.6% (2436 of 2720 participants; 95% CI: 88.4, 90.7), 85.9% (2337 of 2720 participants; 95% CI: 84.6, 87.2), and 90.2% (2453 of 2720 participants; 95% CI: 89.1, 91.3) in the same testing data set. The sensitivities were 61.6% (242 of 393 participants; 95% CI: 59.7, 63.4), 46.9% (226 of 482 participants; 95% CI: 45.0, 48.8), and 36.1% (91 of 252 participants; 95% CI: 34.3, 37.9), respectively. Conclusion A deep learning model applied to volumetric chest CT predicted pulmonary function with relatively good performance. © RSNA, 2023 Supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Park, Yun, Lee, et al. Deep Learning-based Approach to Predict Pulmonary Function at Chest CT. Radiology. 2023. PMID: 36786699. doi:10.1148/radiol.221488

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。