文献速递泌尿生殖技术与安全MR

前列腺MRI图像质量评分系统的多阅片者评估

Multi-reader evaluation of different image quality scoring systems in prostate MRI.
PubMed 文献 · Eur J Radiol · 2023-02-09

本研究回顾性纳入281例活检前接受前列腺MRI的患者,由4名阅片者(2名经验丰富、2名新手)独立评估主观图像质量、PI-QUAL和PSHS评分,以经会阴饱和穿刺活检为参考标准。PSHS评分阅片者间一致性最高(kappa=0.65),且PSHS和PI-QUAL均能评估图像质量对MRI检出临床显著癌敏感度的影响。建议将两种评分系统纳入前列腺MRI报告以提高标准化。

要点

  • PSHS评分阅片者间一致性最高(kappa=0.65),可用于评估图像质量对癌检出率的影响。
  • PSHS与PI-QUAL评分系统侧重点不同,联合纳入报告可提升标准化。
  • 经验丰富阅片者中,PSHS在PI-RADS≥3/≥4时均能评估图像质量对敏感度的影响。

局限性

  • 回顾性研究设计
  • 单中心研究

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate different image quality scoring systems in the assessment of factors limiting diagnostic accuracy of prostate MRI.

METHODS: This retrospective IRB-approved study included 281 patients undergoing prostate MRI prior to biopsy. Four readers (2 experienced, 2 novice) independently reviewed all MRI examinations (n = 295) and assigned scores for subjective image quality (1-5; 1:poor, 5:excellent), the PI-QUAL and the PSHS scoring system. The original PI-RADS scores were extracted from the report and transperineal template saturation biopsy served as histopathological reference.

RESULTS: Inter-reader agreement was found to be good, with PSHS showing highest agreement (kappa: 0.65). The PSHS scoring system performed well assessing the influence of image quality on sensitivity of MR for clinically-significant cancer for the experienced readers using a PI-RADS score cut-off ≥ 3/≥4, as did the PI-QUAL scoring system with a PI-RADS cut-off ≥ 4. For the less experienced radiologist, this was true for PSHS (clinically-significant and all cancers) and PI-QUAL scores (clinically-significant cancers) for a PI-RADS score ≥ 3. PSHS scores were positively associated with the detection of clinically-significant cancer based on a PI-RADS cut-off ≥ 4, OR 1.86 (95 % CI 1.22-2.82), and had the highest Somers' D.

CONCLUSIONS: The PSHS scoring system performed well in assessing the effect of image quality on detection rates, as did the PI-QUAL system. Since both systems focus on different aspects of image quality, their incorporation into prostate MRI reports could further enhance standardization and allow for a reliable assessment of image quality as a potential confounder in prostate MRI.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Hötker, Njoh, Hofer, et al. Multi-reader evaluation of different image quality scoring systems in prostate MRI. Eur J Radiol. 2023. PMID: 36780738. doi:10.1016/j.ejrad.2023.110733

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。