胎儿磁共振成像因孕妇幽闭恐惧或不适而失败的发生率及危险因素
这项单中心回顾性队列研究纳入2012年至2019年间3413例接受胎儿MRI的孕妇,评估因幽闭恐惧或不适导致检查失败的发生率及危险因素。失败率为2.1%,临床指征组失败率低于研究组(0.6% vs 2.4%,P=0.003)。仅因研究目的、较高孕妇年龄和较晚孕周是独立危险因素,而较短检查时间也与失败相关。
要点
- 胎儿MRI因幽闭恐惧或不适而失败的整体发生率低,约2.1%。
- 临床指征检查的失败率(0.6%)显著低于仅研究目的检查(2.4%)。
- 仅研究目的、高龄孕妇和晚孕周是独立危险因素,临床可针对性关注。
诊断标准与关键数值
- 临床指征组与研究组失败率分别为0.6%(4/696)和2.4%(65/2678),P=0.003。
- 仅研究目的aOR 0.05(95%CI 0.01-0.48),P=0.003。
- 较高孕妇年龄aOR 1.07(95%CI 1.02-1.12),P=0.003。
- 较晚孕周aOR 1.46(95%CI 1.16-2.04),P=0.008;较短检查时间aOR 0.77(95%CI 0.63-0.88),P=0.001。
局限性
- 单中心回顾性设计可能限制外推性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the prevalence of and risk factors for failure of fetal magnetic resonance imaging (MRI) due to maternal claustrophobia or malaise.
METHODS: This retrospective cohort study included pregnant women who underwent fetal MRI for clinical indications or research purposes between January 2012 and December 2019 at a single center. One group included patients who completed the entire examination and the other group inlcuded patients who interrupted their MRI examination due to claustrophobia/malaise. We estimated the rate of MRI failure due to maternal claustrophobia/malaise and compared maternal and clinical variables between the two groups. Multiple logistic regression analysis was performed to identify independent risk factors for claustrophobia/malaise during MRI examination in pregnancy.
RESULTS: Among 3413 patients who agreed to undergo fetal MRI, the prevalence of failure because of claustrophobia or malaise was 2.1%. The rate of claustrophobia/malaise in patients who underwent MRI for a clinical indication was lower compared to that in patients who underwent MRI for research purposes only (0.6% (4/696) vs 2.4% (65/2678); P = 0.003). Fetal MRI performed for research purposes only (adjusted odds ratio (aOR), 0.05 (95% CI, 0.01-0.48); P = 0.003), higher maternal age (aOR, 1.07 (95% CI, 1.02-1.12); P = 0.003) and later gestational age at the time of fetal MRI (aOR, 1.46 (95% CI, 1.16-2.04); P = 0.008) were independent risk factors for claustrophobia/malaise. Shorter fetal MRI duration (aOR, 0.77 (95% CI, 0.63-0.88); P = 0.001) was also associated with claustrophobia/malaise during the procedure. Body mass index, ethnic origin, multiple pregnancy, being parous and size of the magnetic bore were not associated with MRI failure due to claustrophobia/malaise.
CONCLUSION: The rate of fetal MRI failure due to claustrophobia or malaise was found to be low, particularly when the examination was performed for a clinical indication, and should not be considered a common problem in the pregnant population. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Dütemeyer, Cannie, Badr, et al. Prevalence of and risk factors for failure of fetal magnetic resonance imaging due to maternal claustrophobia or malaise. Ultrasound Obstet Gynecol. 2023. PMID: 36773302. doi:10.1002/uog.26045
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。